Error LED

Critical faults on the service controller are indicated through the amber error LED.
The error LED has the following two states:
OFF
The service controller is functioning correctly.
ON
A critical service-controller failure was detected and you must replace the
service controller.
The error LED can light temporarily when the node is powered on. If the
error LED is on, but the front panel display is completely blank, wait five
minutes to allow the LED time to turn off before performing any service
action.

SAN Volume Controller 2145-CG8 rear-panel indicators

The rear-panel indicators consist of LEDs that indicate the status of the Fibre
Channel ports, Ethernet connection and activity, power, electrical current, and
system-board errors.
Figure 42 shows the rear-panel indicators on the SAN Volume Controller 2145-CG8
back-panel assembly.
1
Figure 42. SAN Volume Controller 2145-CG8 rear-panel indicators
1 Fibre Channel LEDs
2 Ethernet-link LEDs
3 Ethernet-activity LEDs
4 Ac, dc, and power-supply error LEDs
5 Power, location, and system-error LEDs
Figure 43 shows the rear-panel indicators on the SAN Volume Controller 2145-CG8
back-panel assembly that has the 10 Gbps Ethernet feature.
Figure 43. SAN Volume Controller 2145-CG8 rear-panel indicators for the 10 Gbps Ethernet
feature
1 10 Gbps Ethernet-link LEDs. The amber link LED is on when this port is
connected to a 10 Gbps Ethernet switch and the link is online.