Mitsubishi Electric FR-D720S SC EC Instruction Manual page 245

Fr-d700 series
Table of Contents

Advertisement

Parameter
Forward/reverse signal
NOTES
When Pr. 250 is set to any of "0 to 100, 1000 to 1100", the motor coasts to a stop if the start
command is turned off. (Refer to section 6.8.3.)
The STF and STR signals are assigned to the STF and STR terminals in the initial setting.
The STF signal can be assigned to Pr. 178 "STF terminal function selection" and the STR
signal to Pr. 179 "STR terminal function selection" only.
FR-D700 SC EC
Inverter
Start signal
ON
ON
Function assignment of external terminals
Fig. 6-48:
2-wire type connection (Pr. 250 = 8888)
Time
I001149E