Operation, Cleaning And Maintainence - Vulcan-Hart K40GL Service Manual

K series gas kettles 2/3 jacketed stationary and tilting
Table of Contents

Advertisement

K Series Gas Kettles 2/3 Jacketed Stationary and Tilting - GENERAL
GAS TYPE
Low Speed * - 0.27 to 0.30
Natural
High Speed - 1.91 to 1.98
Low Speed * - 0.27 to 0.30
Propane
High Speed - 1.91 to 1.98
* Low Speed – Blower operates at low speed during trial for ignition (approximately 7 seconds). Ignition is
successful and burner lights. Blower switches to high speed for normal operation approximately 8 seconds
later (total time delay of 15 sec. to high speed) and runs until set point temperature is satisfied. Cycle
repeats upon call for heat.
Kettle Rating
All models listed on front cover have an input BTU rating of 100,000 BTU/HR.

OPERATION, CLEANING AND MAINTAINENCE

Refer to F35461 Installation & Operation Manual for specific instructions. The manual includes:
A page from the Stainless Steel Care and Cleaning Guide for proper care and cleaning of stainless steel.
Draw-Off Valve and Plug Valve dissassembly & cleaning instructions.
GAS SUPPLY PRESSURES
Manifold (in W.C.)
NOMINAL (in W.C.)
7
11
Page 7 of 48
MIN (in W.C.)
MAX (in W.C.)
5
11
F45461 Rev. B (1117)
14
13