System Event Communication Options; Input Supply Fail Tx Delay; Generic Zone Reporting Timer - DSC Skyroute CL3050 Installation & Programming Manual

Standalone wireless communicator compatible with all powerseries keypads
Table of Contents

Advertisement

The generic identifier will be sent with 98 as it's zone number, this is a special
combination recognized by Connect 24 as a generic event. When the generic
zone reporting toggle is disabled, each zone alarm for each zone type will then
send it's own identifier. Default - ON.

[21] System Event Communication Options

NOTE: Section [20], Option [7] must be enabled for these events to be communicated.
Option 1 - Input Supply Failure
If AC power is absent or if DC power drops below 8.8V
terminals, a trouble will be sent after the delay programmed in section [22] has
expired. Default - ON,
Option 2 - Low Battery
If the battery voltage drops below 5.72V
When the battery voltage rises to 5.87V
Default - ON.
Option 3 - Skyroute CL3050 Tamper
Removing the cover on the Skyroute CL3050 will send a tamper reporting code
to Connect 24. Default - OFF.
Option 4 - PC5108 Module Fault
Indicates a Keybus communications fault condition.
Default - OFF.
Option 5 - PC5108 Tamper
Removing the cover on the PC5108 will send a tamper reporting code to Con-
nect 24. Default - OFF.

[22] Input Supply Fail TX Delay

This value determines the delay (default 0700 = 7 hrs) before an input supply fail-
ure reporting code is sent if programmed. See Section [21], Option [1] and Sec-
tion [20], Option [2]. Default - 0700 (=7 hrs)

[23] Generic Zone Reporting Timer

This hex value determines the delay before a generic zone reporting code is sent,
if programmed in Section 20 Option 8.
Note:
Default - 1E (300 seconds / 5 minutes) Range equals 01-FF Hex seconds x 10
There are four separate timers for Burglary, Fire, Panic and Supervisory;
the delay programmed is the same for each timer.
6 Programming Descriptions
a trouble will be sent to Connect 24.
DC
the system will send a restore.
DC
15
All Modes
on the RED and BLK
DC
All Modes
All Modes
Mode 3
Mode 3
All Modes
Modes 2, 3

Advertisement

Table of Contents
loading