MASTER SETTINGS PROGRAMMING
continued
NOTE: If a regeneration occurs while in the Diagnostic screen,
the unit will return to the main screen.
Parameter
Flow Rate
Peak Flow
Displays maximum flow rate of water along
with date and time of occurrence, since last
Totalizer
Displays total volume of water used since
Last Regen
Displays when last regeneration occurred.
Reserve
Displays the reserve volume based on the
reserve type selected under master settings.
*This parameter is only available for meter
Software Version
Displays the software version installed on
No of Regens
Displays how many manually and system
initiated regenerations the system has gone
Regen Interval
Displays the average length of time between
regenerations based on the past four
Daily Usage
Displays average water usage for each day of
the week based on the usage on that day for
Usage Since Regen
Displays water usage since last regeneration.
Last Setting Change
Displays the date and time of the last update
NOTE: Only Peak Flow and Totalizer can be changed - they
can be reset to zero.
NOTE: Totalizer has a maximum value of 99,999,999. If this
number is reached, the Totalizer must be reset to zero
to continue tracking this value.
16 • FLECK 5800 XTR2 Service Manual
Description
Displays the current flow rate.
reset.
last reset.
delayed regeneration type.
the controller.
through since last reset.
regenerations.
the past six weeks.
to Master Settings.
USB Connection for Field Programming
The XTR2 features a USB port that allows you to connect a PC
to the control for field programming and diagnostic parameter
download.
NOTE: Field Programmer software is required for field
programming features. See XTR2 Field Programmer
Manual for more information on using the Field
Programmer software.
Pressing
on the Format screen displays the USB screen.
Figure 32 USB Screen
When the USB screen appears, connect a USB cable to the
USB port on the control circuit board. Connect the other
end of the USB cable to a PC with the Field Programmer
software installed and follow the directions in the XTR2 Field
Programmer manual to complete the connection. Press
return to Master Settings.
NOTE: Do not remove USB cable from computer or control
while connected and transferring data. See the XTR2
Field Programmer manual for proper disconnection
procedure.