C. Connecting Vent Pipe
Reference instructions in the termination kit.
• Install the 3 in. flexible vent pipe(s) down through the
chimney.
• Secure the exhaust flexible vent pipe to the 3 foot section
stainless steel flexible vent pipe using the factory-
installed 3 in. collar in the stainless steel section of pipe
(see Figure 7.1).
• Secure the stainless flexible vent pipe to the exhaust
starting collar on top of the appliance with three screws.
• Use 3 screws to attach the section of inlet air vent to
the inlet collar on the collar slide plate. See Figure 7.1.
NOTE: The collar slide plate may be removed from
appliance to aid installation.
Figure 7.2
• Trim chimney top plate to minimize excess overhang or
bend over flue tile (see Figure 7.2).
• Place 3/8 in. bead of 300 ºF silicone on flue tile top.
14
CUT AND BEND
FLASHING AS NEEDED
TO FIT CHIMNEY
SEALANT
ADHESIVE
Quadra-Fire • QFI30FB-IFT, QFI35FB-IFT Installation Manual • 2555-980 Rev. C • 9/18