Download Print this page

Error Messages - Danfoss BasicPlus2 User Manual

For floor heating

Advertisement

User Guide
The digits indicate the set value as follows:
No.
Parameter settings
P01
Working mode
P02
Temperature control mode
P03
High room temp. limit
P04
Low room temp. limit
P05
Floor temp. limitation mode
P06
Floor temp. limitation setpoint
P07
High floor temp. limit
P08
Low floor temp. limit
P09
Frost protection
P10
Frost protection setpoint
P11
Timer display option
Room temp. display option at
P12
shutdown
P03 to P08 appear on relevant temperature control mode.
10

Error Messages

E1
Room sensor failure
E2
Floor sensor failure
EE
EEPROM failure
Lo
Temperature lower than 0° C
Hi
Temperature higher than 50° C
All relay output will be turned off in all cases.
Danfoss can accept no responsibility for possible errors in catalogues, brochures and other printed material. Danfoss reserves the right to alter its products without notice.
This also applies to products already on order provided that such alterations can be made without subsequential changes being necessary in specifications already agreed.
All trademarks in this material are property of the respective companies. Danfoss and the Danfoss logotype are trademarks of Danfoss A/S. All rights reserved.
Danfoss Floor Heating Hydronics
BasicPlus
Room Thermostats
2
Settings range
01: Manual
02: Advanced Programmable Timer
01: Only room temp.;
02: Room and floor temp.;
03: Only floor temp.
5-35° C (only for 01 and 02 in P02)
5-35° C (only for 01 and 02 in P02)
01: High temp. limitation;
02: Low temp. limitation (only for 02 in P02)
20-45° C (only for 02 in P02)
20-45° C (only for 03 in P02)
20-45° C (only for 03 in P02)
01: Enable; 02: Disable
5-17° C
01: 24 h; 02: 12 h
01: No display current temp.;
02: Display current temp.
VUCUA212
Default
WT-D/DR WT-P/PR
NA
02
01
01
30° C
30° C
5° C
5° C
01
01
35° C
35° C
35° C
35° C
20° C
20° C
01
01
5° C
5° C
NA
01
01
01
03/2015