Characteristics - Fluke Autoranging CombiScope PM3370B Service Manual

Instrument
Hide thumbs Also See for Autoranging CombiScope PM3370B:
Table of Contents

Advertisement

CHARACTERISTICS

2
CHARACTERISTICS
A.
Performance Characteristics
-
Properties expressed in numerical values with tolerances, ranges, or limits stated, are
guaranteed by the manufacturer.
-
Properties expressed in numerical values without tolerances, ranges, or limits stated, represent
the characteristics of an average instrument.
This specification is valid if the temperature has not changed more than + or - 5 °C since the last
-
AUTO CAL, the probe is of the same type as delivered with the instrument, and if the average
factor is 8.
-
For definitions of terms, reference is made to IEC Publication 351-1, 359.
B.
Safety Characteristics
This instrument has been designed and tested in accordance with IEC Publication 348, Safety
Requirements for Electronic Measuring Apparatus, and has been supplied in a safe condition. This
manual contains information and warnings which must be followed by the user to ensure safe
operation and to keep the instrument in safe condition. The instrument has been designed for indoor
use. It may occasionally be subjected to temperatures between +5 °C and 10 °C without degradation
of its safety.
C.
General Characteristics
Overall dimensions:
Height (without feet)
Width (without handle)
Length (without handle and front cover): 481 mm (19 in)
481 mm
TRACE
INTENSITY
TEXT
INTENSITY
TRACE
ROTATION
FOCUS
GRATICULE
ILLUMINATION
POWER
ON
OFF
Figure 2.1
Dimensions
Weight
Operating positions:
a) Horizontally on bottom feet
b) Vertically on rear feet
c) On the carrying handle in three sloping positions
Note:
All items that refer specifically to only one mode (analog or digital) are identified in the
leftmost column with an 'A' or a 'D'.
: 139 mm ( 5.5 in)
: 341 mm (13.5 in)
9.5 kg
(19.7 lb)
AUTO SET
CAL
SETUPS UTILITY
ANALOG ACQUIRE SAVE
STATUS
CURSORS
TRACK
HOLD OFF
LOCAL
TRIGGER
POSITION
DELAYED TIME BASE
DELAY
s
TIME/DIV
ns
DTB
VERT MENU
ALT/CHOP
3
1
2
POS
POS
TRIG1
TRIG2
AUTO
AUTO
AMPL
AMPL
AMPL
RANGE
CH1+CH2
RANGE
INV
mV
mV
AC DC
AC DC
TEXT OFF
ON
GND
ON
GND
V
V
ALL INPUTS MAX 5Vrms at 50Ω/MAX 400Vpk at 1MΩ
Probe Adjust
600mV
1MΩ 25pF
1MΩ 25pF
2kHz
341 mm
RECALL MEASURE MATH DISPLAY HARD COPY
TB MODE
MAGNIFY
X POS
AUTO
RUN/STOP
RANGE
SINGLE_ARM'D
TRIGGER
LEVEL
TIME/DIV
s
ns
TB MODE
VAR
4
POS
POS
TRIG3
TRIG4
AUTO
AUTO
RANGE
RANGE
CH3+CH4
AMPL
INV
mV
mV
mV
mV
AC DC
AC DC
ON
ON
GND
GND
V
V
V
V
1MΩ 25pF
1MΩ 25pF
2 - 1
139 mm
ST7354
9312

Advertisement

Table of Contents
loading

Table of Contents