N. Operating the Blower Control Box with
Snap Disc
1. The blower will turn on/off automatically when set to
AUTO (Figure 17.1).
2. When set to MANUAL, the fan will turn on/off only
when you turn it on or off. This setting over-rides the
internal snap disc.
3. Adjust the speed of the fan by turning the HIGH/LOW
knob to the desired setting.
MANUAL: over-
rides the internal
snap disc
Figure 15.1
O. Blower Operating Instructions
1. Initial (cold) startup:
raising the Burn Rate Air Control all the way up until
it stops and push the Start-up Air Control back until it
stops.
The blower tends to cool the appliance. Leave
the blower off until the burn is well established, i.e., 30
minutes.
2. High Burn Setting: Both controls are open. Burn Rate
Air Control is pulled up and the Start-up Air Control is
fully pushed in. Blower may remain on.
3. Medium High Burn Setting*: Burn Rate Air Control
is closed then opened to 1 inch (pull up )to fully open.
Blower may remain on.
4. Medium Low Burn Setting*: Burn Rate Air Control
is closed then opened to 1/4 inch to 1/2 inch. Leave
the blower off until the burn is well established, i.e., 30
minutes.
5. Low Burn Setting*: Burn Rate Air Control is closed.
Leave the blower off until the burn is well established,
i.e., 30 minutes.
17 August, 2018
Blower Controls Under Ash Lip
AUTO: Fan with turn ON/OFF
automatically and is controlled
by the internal Snap Disc
Open both controls fully by
*NOTE: For burn settings 3 to 5 the Start-up Air Control
needs to be pushed in (Open) then pulled
forward to activate the Automatic Combustion
Control (ACC).
NOTE: For maximum efficiency and lowest emissions,
when operating the blower in either the
automatic or manual setting for the low and
medium low burn settings leave the blower off
until the burn is well established, i.e., 30 minutes.
6. The blower is equipped with a rheostat (speed control).
The highest blower speed is obtained by turning the
rheostat on, then adjusting back towards "OFF" as far
as possible without turning the blower off. For a low
blower speed, turn the control knob clockwise as far as
possible
P. Opacity (Smoke)
This is the measure of how cleanly your appliance is
burning. Opacity is measured in percent; 100% opacity is
when an object is totally obscured by the smoke column
from a chimney, and 0% opacity means that no smoke
column can be seen. As you become familiar with your
appliance, you should periodically check the opacity. This
will allow you to know how to burn as nearly smoke-free as
possible (goal of 0% opacity).
When burning your first fire, you will experience smoke
and odor from the appliance resulting from the curing
of paint and burning off of any oils remaining from
manufacturing.
OPEN WINDOWS DURING INITIAL BURN TO
DISSIPATE SMOKE AND ODORS!
Odors may be irritating to sensitive individuals.
Smoke detectors may activate.