Mounting The Gas Boiler; To Install The Gas Boiler; To Install The Condensate Trap - Daikin Altherma 08CA Installer's Reference Manual

Hybrid heat pump
Table of Contents

Advertisement

7.5

Mounting the gas boiler

INFORMATION
Removing the top plate of the indoor unit makes it easier to
install the gas boiler.
7.5.1

To install the gas boiler

1 Lift the unit from the package.
36kg
2 Remove the top plate from the indoor unit.
3 The bracket to mount the boiler on the heat pump module is
already mounted to the backside of the gas boiler.
4 Lift the boiler. One person lifts the gas boiler on the left side (left
hand on the top and right hand on the bottom) and another
person lift the gas boiler on the right side (left hand on the
bottom and right hand on the top).
5 Tilt the top of the unit at the position of the indoor unit mounting
bracket.
EVLQ05+08CAV3 + EHYHBH05AA + EHYHBH/X08AA +
EHYKOMB33AA
Daikin Altherma hybrid heat pump
4P355634-1C – 2018.06
6 Slide the boiler downwards to fix the boiler bracket onto the
indoor unit mounting bracket.
7 Make sure the gas boiler is fixed properly and well aligned with
the indoor unit.
7.5.2

To install the condensate trap

INFORMATION
The boiler is provided with a 25  mm flexible pipe on the
condensate trap.
Prerequisite: The boiler MUST be opened before installing the
condensate trap.
1 Fit the flexible tube (accessory) to the condensate trap outlet.
2 Fill the condensate trap with water.
3 Slide the condensate trap as far as possible upwards onto the
condensate drain connector below the gas boiler.
7 Installation
Installer reference guide
29

Advertisement

Table of Contents
loading

This manual is also suitable for:

Altherma evlq05

Table of Contents