Vermont Castings 2115 Owner's Manual page 2

Intrepid flexburn wood burning stove
Hide thumbs Also See for 2115:
Table of Contents

Advertisement

Congratulations on your choice of a Vermont Castings Intrepid FlexBurn
craftsmanship seriously. We assure you that your cast-iron Vermont Castings stove has been made with the utmost care
and will provide you with many years of service.
As you become acquainted with your new stove, you will find that its appearance is matched by its functionality, due to cast
iron's unique ability to absorb and radiate heat.
Also, Vermont Castings products are among the cleanest-burning wood stoves available today. However, clean burning
depends on both the manufacturer and the operator. Please read this manual carefully to understand how to properly operate
and maintain your stove.
At Vermont Castings, we are committed to your satisfaction as a customer. That is why we maintain an exclusive network of
the finest dealers in the industry. Our dealers are chosen for their expertise and dedication to customer service. Feel free to
contact your Authorized Vermont Castings Dealer anytime you have a particular question about your stove or its performance.
This manual contains valuable instructions on the operation of your Vermont Castings Intrepid FlexBurn
contains useful information on maintenance. Please read the manual thoroughly and keep it as a reference.
US ENVIRONMENTAL PROTECTION AGENCY
Certified to comply with 2020, particulate emissions standards
at .6g/hr (without catalyst) and .3 g/hr (catalytic).
Please read this entire manual before you install and use
your new stove. Failure to follow instructions may result in
property damage, bodily injury, or even death.
MODEL / MODÈLE: "Intrepid FlexBurn
LISTED SOLID FUEL ROOM HEATER
CHAUFFE-PIÈCE À COMBUSTIBLE SOLIDE RÉPERTORIÉ
Report #/Rapport #0135WS038S / 0135WS038E
Tested to / Testé à: UL 1482-2011 (R2015), ULC-S627-00
APPROVED FOR USE IN MOBILE HOMES IN THE U.S. ONLY
Install and use only in accordance with manufacturer's installation
and operation instructions. Contact local building or fire officials about
restrictions and installation inspection in your area. Install only with legs
provided in accordance with installation instructions.
WARNING: Risk of flame and smoke spillage. Do not obstruct the space
beneath the heater.
Fuel: Use with solid wood fuel only. Do not burn other fuels.
Build a fire directly on hearth only. Do not elevate fire. Keep doors fully
closed or fully open while operating.
Chimney: Use a minimum 6" diameter factory built high temperature
(H.T.) chimney which is listed to UL 103HT (2100°F) or 8" X 8" nominal or
larger approved masonry chimney with flue liner. For Canada ULC S629
Chimney system is required.
Do not connect this unit to a chimney flue serving another appliance.
Chimney Connector: Use a minimum 6" diameter 24 gauge chimney
connector. Install chimney connector at least 18" from ceiling. Refer to
local building codes and Vermont Castings Owner's Guide for precautions
for passing a chimney or chimney connector through a combustible wall
or ceiling.
Floor Protection US: The unit may be installed on a combustible floor
if the bottom heat shield is installed and non-combustible spark & ember
protection is used. The bottom heat shield is required unless the unit will
be installed on a completely non-combustible surface (example: unpainted
concrete over bare earth). There is no required R or K value. The floor
protector should extend 8" (203 mm) from either side of the loading door,
16" (406 mm) from the front of the unit and 6" (152 mm) to the rear of the
unit. The floor protector must extend underneath any horizontal run of
chimney connector and extend 2" (51mm) beyond each side.
Floor Protection Canada: The unit may be installed on a combustible
floor if the bottom heat shield is installed and non-combustible spark &
ember protection is used. The bottom heat shield is required unless the
unit will be installed on a completely non-combustible surface (example:
unpainted concrete over bare earth). There is no required R or K value.
The floor protector should extend 8" (203 mm) from either side of the
loading door, 18" (457 mm) from the front of the unit and 6" (152 mm)
to the rear of the unit. The floor protector must extend underneath any
horizontal run of chimney connector and extend 2" (51mm) beyond each
side.
Do not remove or cover this label.
CAUTION: Burning of materials other than the specified fuels may make
the Catalyst in the combustor inactive. The combustor is fragile, handle
carefully. The performance of the catalytic device or it's durability have not
been evaluated as part of the certification.
Date of Manufacture / Date de fabrication:
2018 2019 2020 JAN FEB MAR APR MAY JUN JUL AUG SEP OCT NOV DEC
Manufactured by / Fabriqué par: Hearth and Home Technologies 352 Mountain House Road, Halifax PA 17032
Mfg. Date
2
2115/2115-CAT"
®
Serial No.
HF
N
de série:
o
Catalytic Combustor Part No. 30007430
Combustion air cannot be obstructed.
Damper must be open before opening doors.
Do not overfire. Glowing parts indicate overfiring.
Replace glass only with 5mm ceramic
Inspect and Clean Chimney Frequently – Under Certain
Conditions of Use, Creosote Buildup May Occur Rapidly.
Installer conformément aux instructions du fabricant. Contacter
CONSIDERABLE DISTANCE AWAY FROM THE APPLIANCE
les autorités locates pour connaître les restrictions et inspections
ATTENTION:
nécessaires. N'installer que les pattes qui sont incluses, en
conformité avec les instructions du fabricant.
Ne pas obstruer l'espace sous le poele.
FONCTIONNEMENT-
Attention: Risque de flammes et de fumée spilage. Ne pas
GARDEZ LES ENFANTS ET LES VÊTEMENTS ÉLOIGNÉS-
obstruer l'espace sous le chauffe-eau.
TOUT CONTACT PEUT ENTRAÎNER DES BRÛLURES DE
Le registre doit être ouvert avant d'ouvrir les portes.
LA PEAU. RÉFÉREZ-VOUS À LA PLAQUE SIGNALÉTIQUE
Combustible: N'utiliser que du bois comme combustible.
Ne pas utiliser d'autres types de combustible. Inspecter et
ET AU MODE D'EMPLOI. GARDEZ LE MOBILIER ET LES
nettoyer la cheminée fréquemment - Sous certainesusages,
AUTRES MATÉRIAUX COMBUSTIBLES BIEN À L'ÉCART DE
l'accumulation de créosote peu se produire rapidement. Garder
L'APPAREIL.
les portes toutes fermées ou toutes ouvertes durant l'opération.
Faire le feu directement sur la grille prévue à cet effet. Laisser
les portes du poêle soit complètement ouverts ou complètement
fermées lors de l'utilisation. Ne pasraccorder le conduit de
cheminée du poêle à une cheminée servant à d'autres appareils.
N'utiliser que les vitres de céramique Vermont Castings en cas
de remplacement de celles-ci.
Protection de plancher Canada: L'unité peut être installée
sur un plancher combustible si l'écran thermique inférieur est
installé et qu'une protection contre les étincelles et les braises
incombustibles est utilisée. L'écran thermique inférieur est
requis à moins que l'unité ne soit installée sur une surface
complètement incombustible (exemple: béton non peint sur de
la terre nue). Il n'y a pas de valeur R ou K requise. Le protecteur
de plancher doit se prolonger de 8 po (203 mm) de chaque côté
de la porte de chargement, de 18 po (457 mm) mm) à l'avant
de l'appareil et de 6 po (152 mm) à l'arrière de l'appareil. Le
protecteur de plancher doit se prolonger sous n'importe quel
passage horizontal de cheminée et s'étendre 2 "(51mm) au-delà
de chaque côté.
Replacer uniquement qu'avec une glace 5mm Vermont Castings.
Attention: Bruler des matières autres que celles spécifiées
pourrait rendre le caralyseur inactif.
Made in U.S.A. of US and imported parts. / Fabriqué aux États-Unis-
Attention: Le catalyseur est fragile, manipulaer avec soin.
d'Amérique par des pièces d'origine américaine et pièces importées.
ECO:
PART # / REV: 3-90-30007343_R1
ORIGINATOR: Spidlet
DATE: 05/16/18
352 Mountain House Road
Halifax, PA 17032
Vermont Castings • Intrepid FlexBurn
Wood Stove. At Vermont Castings we take American
®
BARCODE LABEL
Single Wall Pipe
CAUTION:
HOT
WHILE
IN
Single Wall w/Opt
OPERATION-
DO
NOT
TOUCH-
KEEP
Radiant Shield
CHILDREN AND CLOTHING AWAY- CONTACT
Double Wall Pipe
MAY CAUSE SKIN BURNS- SEE NAMEPLATE
AND INSTRUCTIONS. KEEP FURNISHINGS
Alcove Double
AND OTHER COMBUSTIBLE MATERIALS A
Wall, Ceiling Exit
Vertical, 90°
Elbow Rear Exit
CHAUD
LORS
DU
Straight Backwall
NE
TOUCHEZ
PAS
L'APPAREIL-
Exit
Mur Arrière/Mur De Côté
I
J
K
US ENVIRONMENTAL PROTECTION AGENCY
Certified to comply with 2020, particulate emissions standards at .6g/hr (without catalyst) and .3 g/hr (catalytic). This wood heater needs
periodic inspection and replacement for proper operation. Consult the Owner's Manual for further information. It is against Federal
Regulations to operate this wood heater in a manner inconsistent with operating instructions in the Owner's Manual.
LABEL TICKET
LABEL SIZE: 6.5" H x 13.5" W
ADHESIVE:
MATERIAL: 24 Gauge Aluminum
INK: Black Background Aluminum Lettering
(4) Slotted Holes = .156 x .25
(1) Round Hole = .630
(1) Round Hole = .140
(4) Corners = R.062
Barcode label must have the serial number on it. The
barcode label must be able to read Code 39 Full ASCII.
Owner's Manual_R2 • 2018 - ___ • 07/18
®
Test Lab & Report No.
Model Name
Serial No.
Minimum Clearances to Combustible Materials /
Minimum De Degagement Jusqu'a la construction combustible
A
B
C
D
E
12
14
15
22-1/2
6-1/2
(305mm)
(356mm)
(381mm)
(572mm)
(165mm)
8
10
15
22-1/2
6
(203mm)
(254mm)
(381mm)
(572mm)
(152mm)
10
11-1/2
11
18
6
(254mm)
(292mm)
(280mm)
(457mm)
(152mm)
12
13-1/2
17
24
N/A
(305mm)
(343mm)
(432mm)
(610mm)
11
13
15
22-1/2
N/A
(280mm)
(330mm)
(381mm)
(572mm)
13
15
22-1/2
N/A
N/A
(330mm)
(381mm)
(572mm)
Minimum Alcove dimensions (Double Wall Pipe, Ceiling Exit)
62" (1575mm) Ceiling height, 59-7/8" (1521mm) Wide, 30-7/8" (784mm) deep
dimensions minimales de l'alcôve (tuyau à double paroi, sortie au plafond)
62" (1575mm) Hauteur de plafond, 59-7/8" (1521mm) de large, 30-7/8" (784mm) de profondeur
90° Off Top Up & Out Ceiling Clearance
/ Espace Libre Du Dessus De L'appareil
Backwall/Sidewall /
Corner Installation /
Au Plafond Avec 90° De Courbure
Installation Du Coin
A
E
B
D
F
G
C
Minimum Floor Protection / Protection minimale du plancher
Floor Protection - Type I
Protection de plancher - Type I
Sides (From door opening)
8"
I
Côtes (de l'ouverture de la porte)
Front to Glass
16"
J
Devant, par rapport au verr
K
Rear
6"
Arrière
Wood Stove. It also
®
F
G
H*
12
58-1/2
N/A
(305mm)
(1486mm)
11-1/2
58-1/2
N/A
(292mm)
(1486mm)
11
58-1/2
N/A
(280mm)
(1486mm)
37-1/2
N/A
N/A
(953mm)
58-1/2
18*
N/A
(1486mm)
(457mm)
58-1/2
N/A
N/A
(1486mm)
Horizontal Thru Wall /
Horizontale Au Mur
H*
A
K
I
203 mm
CAN
457 mm
I
152 mm
J
USA
3-90-30007343_R1
3-90-30007345c

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

2115-cat

Table of Contents