Optional Equipment
40
Remove the control panel to access the gas control valve. Remove the regulator from the front of the gas
control valve. Replace with the propane regulator, using the new gasket and screws included with the
regulator. NOTE: Leak test this area after the heater is installed, gas is connected, and the main
burner is lit.
Remove and discard the three screws using a
slotted screwdriver of Torx T-20.
Make the gas line connection, bleed the gas line (if applicable), start the heater and thoroughly leak-test all gas
connections and the gas control valve.
© Travis Industries
a
b
Remove and discard the
regulator, diaphram, spring
and center post.
Slotted
Screwdriver
(or T-20 Torx)
4/20/2018 - 1461
(for qualified installers only)
c
Install the LP regulator. Use the screws
included with the LP regulator. Tighten to
approximately 25 Lbs. torque.
NOTE: Make sure the
regulator gasket is correctly
aligned before installation.
Slotted
Screwdriver
(or T-20 Torx)
d
Place the LP label on top of
the control cover near the gas
control valve.
Northfield MV