II. AUX OUTPUT
Switch "5" controls the Aux output operating mode.
AC – Switch "5" down (off) - factory default setting.
DC – Switch "5" up (on).
In AC mode, the Aux accessories will operate only when AC power is applied to the battery charger.
In DC mode, the Aux accessories will operate when the AC power is on or off. The Aux accessory
is powered by the charger while AC power is applied to the charger and from the vehicle's battery
when no AC power is applied.
III. REMOTE BATTERY CHARGE CONDITION INDICATOR (Standard equipment)
This remote indicator shows the charge condition of the battery in 10 levels from "LOW CHARGE"
to "FULLY CHARGED". This device indicates a defective battery when the bar graph does not rise
to the "FULLY CHARGED" level after an extended period of charging.
NOTE: If a battery is being charged with an external load of 1.5 to 4 amperes across its terminals,
the bar graph may move down 1 or 2 levels. This does not indicate a defective battery. To avoid this,
either reduce constant load draws or consider an external Battery Saver. Please contact Kussmaul
Electronics for further details.