New functions in firmware version 2.10

The following new functions have been added in firmware version 2.10.
0 A cascade function that allows simultaneous recording/playback operations on two units is now supported.
0 The
screen now shows the cascade status.
INFORMATION

Cascade function support

A cascade function is now supported. This allows simultaneous recording/playback operations with sample-precise synchronization on
two units that are connected to the same network. Cascade operation of up to two units is possible with the following simultaneous re-
cording/playback channel limits.
0 When the sampling frequency is 44.1/48 kHz, up to 64 channels on 2 units (128 total channels)
0 When the sampling frequency is 88.2/96 kHz, up to 32 channels on 2 units (64 total channels)
Cascade function setup
Use the
page added to the menu screen to make cascade function settings and check its status.
CASCADE
CASCADE STATUS
This shows the cascade status.
Cascade status
Cascade OFF
Offline
(No Network)
Offline
(Duplicate Slave)
Offline
(Duplicate Master)
Comms Lost with
Slave
Offline (No
Slaves)
Offline (No Mas-
ter)
Syncing...
Waiting...
OK (N active)
2
TASCAM DA-6400/DA-6400dp
DA-6400/DA-6400dp
ERROR/ALERT classification
---
ERROR
ERROR
ERROR
ALERT
ALERT
ERROR
ERROR
ERROR
---
Contents
The cascade function is off.
Cascade operation is not possible because it is not connected to a
network.
Proper cascade operation is not possible because multiple units are
set to the same cascade slave ID.
Cascade operation is not possible because multiple units are set as
the cascade master.
The cascade master is no longer able to communicate to one of the
cascade slaves.
Cascade operation is not possible because no unit set to be a cas-
cades slave could be found on the network.
Cascade operation is not possible because no unit set to be the cas-
cade master could be found on the network.
Cascade synchronization is being prepared.
The unit is waiting for cascade to be ready.
Cascade synchronization is working properly for N number of units.