Advanced Entry Calibration (continued)
For example, if your
compiled data had
the values shown in
this table, Gain
Number 8 would be
chosen because it
has the highest
Difference Value
(146), where both
the Label Value and
the TOF Value are
above 20.
Step
Action
13
Using the
select the Gain Number
determined in Step 12.
Press the
select the setting.
14
Place the media in the
Media Sensor. Record the
sensor reading and label it
'P' (paper).
Place the backing, mark, or
notch in the sensor. Record
the reading and label it 'G'
or 'M' (Gap or Mark).
Remove all media. Record
the reading and label it 'E'
(Empty).
15
Press the
Then press the
Key.
Adjustments and Maintenance
Gain
Number
00
01
02
03
04
05
06
07
08
09
10
...
31
32
Displayed Message
!
Key,
HBJO!USBO!!!!!!=zzz?!
+19!!!!!!!!!)1!.!42*
!
Or, for reflective media:
Key to
HBJO!SFGM!!!!!!=zzz?!
+19!!!!!!!!!)1!.!42*
!
HBJO!USBO!!!!!!=zzz?!
+19!!!!!!!!!)1!.!42*
!
Or, for reflective media:
HBJO!SFGM!!!!!!=zzz?!
+19!!!!!!!!!)1!.!42*
!
Key.
BEWBODFE!FOUSZ!
TFOTPS!MFWFMT
!
Label
TOF
Value
Value
255
254
251
240
241
213
231
182
219
150
212
119
200
88
189
58
178
32
167
19
156
17
...
...
116
14
112
14
This example uses Gain Number
8.
!
Selection is denoted with an '*'.
!
Where 'yyy' is a numerical value
representing the current sensor
!
reading.
!
The sensor readings must be
!
manually entered into the printer
now.
2-16
Difference
Value
1
11
28
49
69
93
112
131
146
N/A
N/A
...
N/A
N/A
Comment