Pioneer AVIC-X3/XU/EW5 Service Manual page 90

Dvd multimedia av navigation server, dvd multimedia av navigation head unit
Table of Contents

Advertisement

1
2. [X-3121 Servo Test (1-0)] : Power-On Status Screen
A
B
Note:
If no operation is made in about 10 seconds after LD-ON, the system performs LD-OFF automatically.
If you perform Focus Close while the LD is OFF, it will result in an error.
Also during Focus Search (S-curve measurement mode), the safety system is activated if LD-OFF does not occur
within 10 seconds. Therefore, LD goes off in 9 seconds, also when Focus Search is performed after LD-ON.
If you perform Focus Close after Focus Search operation (S-curve measurement mode), turn the power off once,
and then turn it on, before performing Focus Close.
Note:
You cannot perform operation till completion of the display of values from FE Offset to VIN_10.
Note:
[1] cannot be executed, unless [5] command is executed beforehand.
C
[1] Transition to Focus Close 1 status
[2] Execution and stop of Focus Search operation
[3] Execution and stop of CRG+
[4] Execution and stop of CRG-
[5] LD On/OFF
[6] Execution of CRG_HOME
[OK] Execution/Stop
[BACK] 1, [X-3212 Servo Test] : Return to the Power Off Status screen.
3. [X-3212 Servo Test (2-0)] : Focus Close 1 Status Screen
D
E
Note:
The data values will change upon execution of a command.
Note:
You cannot perform operation till completion of the display of values from FE MAX to TE MIN.
[1] Transition to Focus Close 2 status
[2] Execution of Focus Jump
[3] Execution and stop of CRG+
[4] Execution and stop of CRG-
[OK] Execution/Stop
[BACK] 1, [X-3212 Servo Test]: Return to the Power Off Status screen.