Pioneer AVIC-X3/XU/EW5 Service Manual page 147

Dvd multimedia av navigation server, dvd multimedia av navigation head unit
Table of Contents

Advertisement

5
- TP DATA INITIALIZE
Screen configuration
Outermost circumference and 16 point calibration data are returned to the initial value.
If already set, " " will be displayed in front of each item. It goes away upon clearing of the setting.
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32
1
2
3
4
5
6
7
8
9
The functions by the items selected are as follows.
RANGE INIT
The factory preset outermost circumference setting is initialized.
CALIB INIT
The factory preset calibration is initialized.
USER RANGE INIT
The user preset outermost circumference setting is initialized.
By this action, the factory preset outermost circumference setting is used.
USER CALIB INIT
The user preset calibration setting is initialized.
By this action, the factory preset outermost circumference setting is used.
Conditions for the adjusted mark ( ) to light on.
RANGE INIT
The same condition as the item for outermost circumference adjustment in the top MENU.
CALIB INIT
The same condition as the item for line touch panel verification in the top MENU.
USER RANGE INIT
In case the user outermost circumference adjustment made a normal ending.
USER CALIB INIT
In case the user calibration made a normal ending.
Conditions for the adjusted mark ( ) to go out.
RANGE INIT
The same condition as the item for outermost circumference adjustment in the top MENU.
CALIB INIT
The same condition as the item for line touch panel verification in the top MENU.
USER RANGE INIT
In case the user outermost circumference adjustment has never been conducted.
When the EEPROM initialization is made.
In case the user outermost circumference adjustment value initialization was conducted in the initialization menu.
In case the outermost circumference adjustment made a normal ending.
In case the calibration adjustment made a normal ending.
USER CALIB INIT
In case the user calibration adjustment has never been conducted.
When the EEPROM initialization is made.
In case the user calibration adjustment value initialization was conducted in the initialization menu.
In case the outermost circumference adjustment made a normal ending.
In case the calibration adjustment made a normal ending.
Operational specifications
Select each item by the MENU key and the MAP key.
The function of the item selected by the MENU key is executed.
When "RETURN TO MENU" is executed, the screen will return to the top MENU.
5
6
T P
D A T A
R A N G E
I N I T
C A L I B
I N I T
U S E R
R A N G E
U S E R
C A L I B
R E T U R N
T O
[ E N T E R ]
[ U P
D O W N ]
AVIC-N4/XU/UC
6
7
I N I T I A L I Z E
I N I T
I N I T
M E N U
U S E
F U N C T I O N
M O V E
C U R S O R
7
8
A
B
C
D
E
F
147
8