Pentair ULTRATEMP ETi 220 Installation And User Manual page 8

Hybrid heater
Table of Contents

Advertisement

4
Recommended Clearances
OUTDOOR INSTALLATION
VENTING GUIDELINES
12"
(30.5cm)
Building
ULTRATEMP ETI™ Hybrid Heater Installation and User's Guide
(cont.)
(1.2m)
4'
(1.2m)
Force
Air Inlet
SIDE VIEW
Roof Overhang
From building wall
Exhaust Grill
(Vent)
Building
Vent Termination:
Must be at least 3 ft. (0.9 m) above any forced
air inlet located within a 10 ft. (3.5 m) radius.
Must be located 12 in. (30.5 cm) away from the building
wall and the following distances away from any building
wall openings, included but not limited to vented eaves,
doors, windows, gravity air inlet:
From window
4 ft. (1.2 m) below,
or door
4'
4 ft. (1.2 m) horizontally
Property Line
4'
(1.2m)
ROOF OVERHANG
12"
(30.5cm)
Figure 3:
Vent Clearances