16

CONNECTING TO AN AUTOMATION SYSTEM

Remote Operation

The UltraTemp ETi™ Hybrid Heater may be connected
to an automation system via the remote spade
terminals on the back of the control board (see page
17) or via the RS-485 communication connector on
the back of the control board (see page 18). Refer to
the EasyTouch
®
Control System Installation and User's
Guide for more information.
Remote connection via the RS-485 connector is only
available on EasyTouch software version 2.169 or
later. All other automation packages must connect
via the ¼ in. "Spade" terminals (spade connector not
supplied).

Relay Remote Controls

Electrical wiring must be in accordance with the latest
edition of the NEC (NFPA 70) in the United States
and CEC (CSA 22.1) in Canada, unless local code
requirements indicate otherwise.
To connect remote control equipment to the
heater, perform the following steps:
1. Turn off the power to both the remote pool/spa
control system and the heater.
2. Remove the side panel of the heater cabinet, (you
do not need to remove the star-head screw at the
top left corner).
ULTRATEMP ETI™ Hybrid Heater Installation and User's Guide
3. Remove the four (4) bezel retaining screws from
above the bezel and rotate the bezel downward.
This will allow you to access the Remote terminals
on the back of the heater control board for the
remote control installation.
4. Run the wires from the pool/spa remote control
system into the upper electrical compartment.
5. Connect the wiring from the pool/spa remote
control system to the heater remote control
terminals using ¼ in. (6.4 mm) "Spade" connectors
as shown in the image below.
6. Rotate the bezel back into position and reinstall
the four (4) retaining screws.
7. Replace the side panel.
8. Restore power to the heater and the pool/spa
remote control system.
9. Press the MENU SELECT button repeatedly to
scroll to the Remote Mode screen. Toggle the
selection by pressing one of the arrows until the
screen displays "Relay".
10. Turn on the heater.
1/4 in. "Spade"
Connectors