Basic Operating Instructions; Turning Off Gas To The Heater - Pentair ULTRATEMP ETi 220 Installation And User Manual

Hybrid heater
Table of Contents

Advertisement

22

Basic Operating Instructions

1. STOP! Read the safety information on (page 20).
2. Turn off all electric power to the appliance.
3. This appliance does not have a pilot. It is equipped
with an ignition device which automatically lights the
burner. Do not try to light the burner by hand.
4. Remove the access panels by removing the Phillips
head screws on each panel, then sliding the panels
down and out.
5. Locate the toggle-style valve and pull the toggle
toward you to turn gas off, see Figure 19.
GAS
OUT
6. Wait five (5) minutes to clear out any gas. If you
then smell gas, STOP! Follow directions given in
WHAT TO DO IF YOU SMELL GAS at the top of the
previous page. If you don't smell gas, go to the next
step.
7. Push the toggle switch away from you to switch the
gas on.
8. Replace the service panels. All panels must be in
place when operating the heater.
9. Set 3-way valves on inlet and outlet to pool or spa,
as appropriate.
10. Turn on all electric power to the appliance.
11. Ensure the pump is running.
12. Press ON/OFF button on the operating control.
13. Select operation mode.
ULTRATEMP ETI™ Hybrid Heater Installation and User's Guide
Figure 19
Gas control is
shown ON. Push
toggle switch to
your left to switch
OFF.
GAS
IN
14. Set the thermostat to desired setting.
Note: Setpoint must be above actual water
temperature or burner will not fire.
15. The blower should come on immediately, and after
about 15 seconds, the burner should fire. When
operating for the first time, the burner may not fire
on the first try because of air in the gas line. If it
does not fire at first, push the ON/OFF button, wait
five minutes, and again push the ON/OFF button.
The burner should fire after about 15 seconds.
You may have to repeat this until all of the air has
cleared the gas line.
16. The burner should fire until the pool/spa temperature
reaches the desired temperature set on the
thermostat. The blower will continue to run for
about 60 seconds after the burner shuts off. If any
of the safety interlocks should open during burner
operation, the burner shuts off immediately, but
the blower continues to run for about 60 seconds.
Should overheating occur or the gas supply fail to
shut off, turn off the manual gas control valve to the
appliance.
17. If the appliance will not operate, follow the
instructions Turning Off Gas to the Heater below,
and call your service technician or gas supplier.
18. If the electrical power is shut off to the heater while
it is running, once power is restored, the heater will
power up with the previous programed settings.

Turning Off Gas to the Heater

1. Press the ON/OFF button on operating control.
2. Switch off all electric power to the unit.
3. Remove the service panels.
4. Toggle-Style Valve: Pull toggle toward you to turn
gas off, see Figure 19.
5. Replace the service panels.

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents