Service Menu Tree Guide And Navigation; Using The Service Menus - Pentair ULTRATEMP ETi 220 Installation And User Manual

Hybrid heater
Table of Contents

Advertisement

Service Menu Tree Guide
(Press UP and DOWN Arrows Simultaneously)
LANGUAGE - IDIOMA - LANGUE
ENGLISH / ESPANOL / FRANCAIS
VERSION SOFTWARE
REV. ____
INTELL ADDRESS
ADDRESS = 1-16
START DELAY
TIME = 0 - 5 MINS
ECO TIME
TIME = 1 - 6 HRS
BOOST TEMPERATURE
TEMP = 5 - 10
TEMPERATURE SCALE
FAHRENHEIT / CELSIUS
WATER TEMP OFFSET
OFFSET = -2 TO +2
DEFROST
ENABLE / DISABLE
WF HP LP PL SP
1
1
1
0
0
FAN COMP GAS REV
1
1
1
0
CFS
TF
HLS
1
1
1
AFS
VAL
AGS
1
1
1
TEMP. RECORD
HOUR # ___ ___°F
RUN TIMES/COUNTS
PRESS MODE
TO EXIT SETUP
1
HEAT PUMP INPUT STATUS
WF = WATER FLOW SWITCH
HP = HIGH REFRIGERANT
PRESSURE SWITCH
LP = LOW REFRIGERANT
PRESSURE SWITCH
PL = POOL REMOTE
SP = SPA REMOTE
*
2
OUTPUT STATUS
FAN - FAN
COMP - COMPRESSOR
GAS - GAS HEAT
*
REV - REVERSING VALVE
3
GAS INPUT STATUS
CFS - CONDENSATE FLOAT
SWITCH
TF - THERMAL FUSE
HLS - HIGH LIMIT SWITCH
4
GAS INPUT STATUS (cont.)
AFS - AIR FLOW SWITCH
VAL - GAS VALVE
AGS - AUTO GAS SHUTOFF
*
NOTE: These settings
are only active when
Efficiency Mode is set to
1
"Hybrid"
2
3
4
Navigating the Service Menu Screens
Press the UP and DOWN arrows simultaneously. If no activity
is detected after 15 seconds, the display will return to the main
screen.
Language Selection
Displays the language selected. Select either English, Spanish
or French using the UP and DOWN arrows.
Software Revision
Displays the software revision level loaded on the control board.
Intell Address
Heater RS-485 Communications Address which must match
the address used in the EasyTouch automation controller
being communicated with. Adjustable from 1 to 16 using the
UP and DOWN arrows.
Start Delay
Displays the time period between heater start cycles. Adjustable
from 0 to 5 minutes using the UP and DOWN arrows.
Eco-Time
Displays the period of time the heat pump will attempt to reach
an active set point before the gas heater activates. Adjustable
from 1 to 6 hours
using the UP and DOWN arrows.
Boost Temperature
Displays the temperature difference allowed between incoming
water temperature and active set point. If the temperature
difference exceeds this setting the gas heater will activate.
Adjustable from 5-10 degrees
Temperature Scale
Determines if the water temperature actual reading and set
point is displayed in degrees Fahrenheit or Celsius. Adjusted
between Fahrenheit and Celsius using the UP and DOWN
arrows.
Temp Offset
Adjusts the measured water temperature up or down to allow
the operator to match the heater's displayed temperature to
a remote temperature monitoring device. The offset can be
varied from -2 to +2 using the UP and DOWN arrows.
Defrost Screen
Allows the user to Enable/Disable Defrost feature.
Heat Pump Input Screen and Output Screen
1
Diagnostic displays showing the status of the input sensors
2
and output devices. The number one (1) is displayed when the
associated input/output is on and zero (0) is displayed when
the associated input/output is off.
Gas Input Status Screens
3
Diagnostic displays showing the status of gas-related input
4
sensors. The number one (1) is displayed when the associated
input is on and zero (0) is displayed when the associated
input is off.
Temperature Log and Run Time Counters
These screens display a list of compressor, fan and valve run
times, and a history of measured water temperatures. This
information is provided so the user can easily track performance
and troubleshoot issues.
Exit Set Up
Pressing the MODE button while this screen is displayed
returns the display to the Efficiency Mode Screen.
ULTRATEMP ETI™ Hybrid Heater Installation and User's Guide