INSTALLATION INSTRUCTIONS

1. All electrical work and materials
must comply with the National
Electric
Code
Occupational Safety and Health
Act (OSHA), and all state and local
codes. Canadian installations must
comply with Codes Canada and
provincial codes.
2. Use copper conductors only.
3. DO NOT install the heater directly
above bathtub or sink. DO NOT
install in shower stall area. Cadet
recommends installing your heater
at least 2 feet (61 cm) away to
prevent contact with water.
4. Heater must be connected to a
GFCI protected branch circuit when
installed in a bathroom.
5. Heater must be installed in a wall
can:
Wire Strippers
Drill and Drill Bits
Volt Meter
A multi-purpose tool or something to cut your existing drywall or gypsum board.
high-temperature
safety shutoff
built-in timer
(NEC),

TOOLS REQUIRED

Wire Connectors
Tape Measure
PARTS OF YOUR HEATER
3
Model CB - wall can model CC or
CCSM
the
6. DO NOT install the heater in a floor,
in the ceiling, below a towel bar,
behind a door, or anywhere the air
discharge may be blocked in any
manner.
7. To reduce the risk of fire, do not
store or use gasoline or other
flammable vapors and liquids in the
vicinity of the heater.
8. Connect
grounding screw provided. Keep all
foreign objects out of heater.
9. Electric heaters must be installed
on a circuit dedicated to electric
heaters, they cannot share a
circuit with outlets, lights, or other
appliances.
1½" Wood Screws
Hammer
heater element
fan and
motor
built-in thermostat
grounding
lead
Straight and Phillips
Screwdrivers
½" Cable Clamp
Connector
Stud Finder