H S M 2 H O S T I n s t a l l a t i o n M a n u a l
1.
Enter Installer Programming section [804] > [802].
2.
Select one of the following options by scrolling or entering the hotkey:
Table 2-2 Wireless Supervisory Window Options
00
Enabled/Disabled
01
After 1 Hour
02
After 2 Hour
03
After 4 Hour
04
After 8 Hour
05
After 12 Hour
06
After 24 Hour
3.
Press [*] to accept the selection.
4.
Press [#] to exit the section.
NOTE: For UL Residential Burglary (UL1023), Home Health Care (UL1637), ULC Residential Burglary (ULC/ORD-C1023) installations the
maximum supervision window shall be set to 24h.
For UL Residential Fire (UL985) installations the maximum supervision window is set to 200s.
For UL Commercial Burglary (UL1610/UL365), Residential Fire (UL985) and ULC Residential Fire (ULC-S545) the maximum supervision
window shall be set to 4h.
2.1.5 [804]>[810] Wireless Option 1
To program wireless options:
1.
Enter Installer Programming section [804] > [810].
2.
Select one of the following options by scrolling or entering the hotkey:
Table 2-3 Wireless Options
01
RF Delinquency On: the system cannot be armed if a wireless supervisory
trouble exists.
Off: wireless supervisory troubles do not prevent arming.
02
Wireless Supervi-
On: If a supervisory or jamming trouble occurs during
sory/ RF Jam
Away arming, the siren activates and the event is logged
Alarm
and reported.
Off: supervisory or RF jam troubles during Away arming
do not activate the siren or get logged and reported.
03
Module Tamper
On: device tampers are logged and reported.
Off: device tampers are not logged or reported.
04
Fire Supervision On: fire devices are supervised every 200 seconds. If the
device fails to report within this window, a supervision
trouble is generated.
Off: fire devices follow the supervision window pro-
grammed in section 802.
3.
Press [*] to accept the selection.
Press [#] to exit the section.
2.1.6 [804]>[821]-[841] Wireless Device Defaults
Wireless device default parameters used during enrollment can be changed at any time. Once default values are changed, any new devices
enrolled inherit the modified default values. The defaults of devices already enrolled are not changed.
To modify wireless device defaults:
1.
Enter Installer Programming section [804] then navigate to one of the following sub-sections using the scroll keys or by entering a hotkey:
Table 2-4 Device Type Sub-Sections
Sub-Section
Description
821
Contacts
822
Motion sensors
824
Smoke detectors
827
Flood detectors
828
Temperature detectors
829
Wireless keys
830
Sirens
841
Motion camera (not UL/
ULC evaluated)
NOTE: Not all devices are UL/ULC listed. See Compatible Wireless Devices on page I for details.