2.1 Wireless Device Setup and Programming

This section describes how to enroll and program wireless devices such as contacts, motion sensors and sirens on the alarm panel.
2.1.1 [804]>[000] Enroll Wireless Devices
Once the HSM2HOST is installed and enrolled on the alarm panel, wireless devices can be enrolled using the following method:
1.
Enter Installer Programming section [804] > [000]:
2.
When prompted, either activate the device (see device installation sheet) to enroll immediately or enter a device serial number. Do the latter
to pre-enroll devices then enroll them later at the customer site.
The alarm panel determines the type of device being enrolled and presents the appropriate programming options.
Table 2-1 Wireless Device Options
Device Type
Programming Options
Zone
(01) Zone type
(02) Partition assignment
(03) Zone label
Wireless key
(01) Partition assignment
(02) User label
Siren
(01) Partition assignment
(02) Siren label
Repeater
(01) Repeater label
3.
Use the scroll keys or type in the corresponding number to select an option.
4.
Scroll through the available selections, key in a number or enter text as appropriate.
5.
Press [*] to accept and move to the next option.
6.
Once all options are configured, the system prompts to enroll the next device.
Repeat the process described above until all wireless devices are enrolled.
NOTE: The configuration options listed above can be modified using [804] > [911] Modify Device.
1.1.2 [804]>[001]-[716] Wireless Device Configuration
To configure wireless devices:
1.
Enter Installer Programming section [804] then select one of the following sub-sections:
Sub-Section
001-128
Configure wireless zones
551-556
Configure wireless sirens
601-632
Configure wireless keys
701-716
Configure wireless keypads
2.
Select a device to configure using the scroll keys or go directly to a specific device by entering a hotkey.
3.
Use the scroll buttons or enter a hotkey to select a configuration option for the device.
4.
Press [*] to accept and move to the next option.
5.
Once all options are configured, the system returns to the base configuration menu.
Repeat the process described above to configure other wireless devices.
2.1.3 [804]>[801] RF Jam Detect
RF jam detection (continuous interfering transmissions on the radio network) can be turned on or off. When on, RF jamming is logged and
reported.
To configure RF jamming:
1.
Enter Installer Programming section [804] >[801].
2.
Select one of the following options by scrolling or entering the hotkey:
00
Enabled/Disabled
01
UL 20/20-USA
02
EN 30/60-Europe
03
Class 6 30/60-British As EN (30/60) but reported only if the jamming duration
3.
Press [*] to accept the selection.
4.
Press [#] to exit the section.
2.1.4 [804]>[802] Wireless Supervision Window
This option is used to program the length of time a wireless device can be absent from the system before a fault is generated.
NOTE: For EN installations, 1 hour or 2 hours must be selected.
To program the Wireless Supervisory Window:
Description
Jamming detection and reporting is enabled/disabled
NOTE: Must be Enabled for UL/ULC listed installations.
Continuous RF jamming for 20 seconds
30 seconds of accumulated jamming within 60 seconds
exceeds 5 minutes
W i r e l e s s D e v i c e S e t u p a n d P r o g r a m m i n g