Led Display Specifications Of The Rd77Ms - Mitsubishi Electric MELSEC iQ-RD77MS2 User Manual

Melsec iq-r series; simple motion module
Hide thumbs Also See for MELSEC iQ-RD77MS2:
Table of Contents

Advertisement

1.1

LED Display Specifications of the RD77MS

This section lists the LED display specifications of the RD77MS.
: OFF, : ON, ●: Flashing
Simple Motion
module status
Normal operation
Operation failure
Online module change
*1 When all axes are stopped or on standby, the AX LED turns OFF.
*2 When any of the axes is in operation, the AX LED turns ON.
*3 When an error occurs in any of the axes, the AX LED is flashing.
1 PART NAMES
20
1.1 LED Display Specifications of the RD77MS
LED display
RUN 
AX1 
ERR 
AX2 
AX3 
AX4 
*1
AX1-8 
*1
AX1-16 
RUN 
AX1 
ERR 
AX2 
AX3 
AX4 
*2
AX1-8 
*2
AX1-16 
RUN 
AX1 ●
ERR 
AX2 
AX3 
AX4 
*3
AX1-8 ●
*3
AX1-16 ●
RUN 
AX1 
ERR ●
AX2 
AX3 
AX4 
AX1-8 
AX1-16 
RUN ●
AX1 
ERR 
AX2 
AX3 
AX4 
AX1-8 
AX1-16 
RUN 
AX1 
ERR 
AX2 
AX3 
AX4 
AX1-8 
AX1-16 
Description
The axes stopped
The axes on standby
The axis in operation
Minor error
Moderate error
Watchdog timer error
Module remove selection in operation
Module change in operation