Code
Error Contents and Cause
(SD0)
Data of special function module to be
2113
simulated is not set in the simulation
data.
There is no boot file in the drive
designated by the parameter enabled
2210
drive switch even though the Boot DIP
switch is ON.
• A memory card was removed without
switching the memory card in/out
switch OFF.
2300
• The memory card in/out switch is
turned ON although a memory card is
not actually installed.
• The memory card has not been
formatted.
2301
• Memory card format status is
incorrect.
A memory card that cannot be used
2302
with the CPU module has been
installed.
The file designated at the PLC file
2400
settings in the parameters cannot be
found.
Corrective Action
Read the individual information of the
error using a peripheral device, and
check the special function module /
special function module dedicated
instruction (network instruction) that
corresponds to the value (program error
part) to make modification.
Check and correct the valid parameter
drive settings made by the DIP
switches.
Set the boot file to the drive specified by
the parameter drive DIP switches.
• Remove memory card after placing
the memory card in/out switch OFF.
• Turn on the card insert switch after
inserting a memory card.
• Format memory card.
• Reformat memory card.
• Format memory card.
• Reformat memory card.
• Check memory card.
• Read the individual information of the
error using peripheral device, check
to be sure that the parameter drive
name and file name correspond to
the numerical values there
(parameter number), and correct.
• Create a file created using
parameters, and load it to the CPU
module.
84
Corresponding
CPU
QnA
QnA
QnA
QnA
QnA
QnA

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Q2ascpu-s1Q2ashcpuQ2ashcpu-s1