Advertisement

(b) When wiring with cable that exceeds 2 m (6.56 ft.), but is 10 m (32.81 ft.)
or less
• Ground the shield section of the external wiring cable with the cable
clamp.
(Ground the shield at the closest location to the A1SD75 external
wiring connector.)
• Install a ferrite core.
• Wire the external wiring cable to the drive unit and external device with
the shortest practicable length of cable.
(c) Ferrite core and cable clamp types and required quantities
• Cable clamp
Type: AD75CK (Mitsubishi Electric)
• Ferrite core
Type: ZCAT3035-1330 (TDK ferrite core)
• Required quantity
Cable length
Within 2 m (6.56 ft.)
2 m (6.56 ft.) to 10m (32.81 ft.)
Inside control panel
AD75CK
External wiring connector
Ferrite core
Cable clamp
External wiring cable (2 m to 10 m (6.56 ft. to 32.81 ft.))
Prepared part
AD75CK
AD75CK
ZCAT3035-1330
20 30cm
(7.87 11.81inch)
9
Drive unit
Required Qty
1 axis
2 axes
3 axes
1
1
1
1
1
2
1
1
3