Installer Lockout Enable

When this feature is enabled, performing a hardware or software reset to restore the system's factory programming
will not reset the Installer's Code or the Downloading Access Code.
To enable this feature, enter Section [90]. After entering Section [90], enter the [Installer's Code] to confirm activation
of this feature. If the Installer's Code is not entered correctly, the keypad will sound a single long tone to indicate the
error and the feature will not be enabled.
A system that has this feature enabled will provide an audible indication upon power-up by clicking the telephone line
relay 10 times. When applying power to the system when performing a hardware reset (see Section [99]), the telephone
line relay will sound the 10-click indication twice.
Ensure that the new Installer's Code has been entered correctly before enabling this feature as there is no way
of re-entering the Programming Mode without the new Installer's Code.
[91]

Installer Lockout Disable

Entering [91][Installer's Code] while in the Installer's Programming Mode will disable the Installer Lockout feature
described in Section [90]. If the Installer's Code is not entered correctly, the keypad will sound a single long tone to
indicate the error and the Installer's Lockout will not be disabled.
NOTE: Control panels returned to DSC with the Installer Lockout feature enabled and no other apparent problems will
be subject to an additional service charge.
[99]

Factory Default

This section is used to reset the EEPROM memory to the original factory default values. After entering Section [99],
enter the [Installer's Code] to confirm activation of this feature. If the Installer's Code is not entered correctly, the keypad
will sound a single long tone to indicate the error and the factory default will not be performed.
Hardware Reset of EEPROM Memory to Factory Defaults
If the Installer's code is lost through inadvertent programming, the only means of reprogramming the system is via a
hardware reset. If the installer's lockout is enabled, there is no way to reprogram the system without entering the correct
installer's code. Follow the sequence outlined below to reset the panel to factory default conditions.
Power unit down by removing both AC and battery power.
1
2
Using a jumper, short the PO1 and Zone 1 terminals together.
3
Apply power to the PC2585.
4
Wait for 10 seconds then remove the connection between the PO1 and Zone 1 terminals.
5
The system will have reloaded the EEPROM with the factory default codes.