Trane ECOWISE RTAF SE Installation Operation & Maintenance page 73

Air-cooled helical-rotary chillers 300 - 1600 kw
Table of Contents

Advertisement

Table 19 – General data for free cooling option (continued)
Partial Free Cooling type (11)
Sound power levels
Coils quantity (6)
Coils quantity (7)
Summer nominal water flow
Discharge
Summer & Winter unit pressure drop
Glycol Pump Max Power input (kW)
Measurement conditions:
Glycol Pump Max Amps @ 110 V
Measurements taken in a room adjacent to the room containing the FWD, at the outlet of the rectangular duct (1.5 m
Freeze protection - Max Power input
long) fixed to its discharge opening.
Freeze protection - Max Amps
Additional Free Cooling weight (without water) (6)
Fan
Additional Free Cooling weight (without water) (7)
Unit
speed
Additional water content (without Evap.) (6)
1
Additional water content (without Evap.) (7)
FWD 08
2
Glycol content (6)
3
1
Glycol content (7)
FWD 10
2
Additional baseframe length (6)
3
Additional baseframe length (7)
1
FWD 12
2
3
1
FWD 14
2
3
1
FWD 20
2
3
(1) SE-SN/HE-SN/HE-LN
(2) SE-LN/XE-SN/XE-LN/HSS-SN/HSS-LN/HSE-SN/HSE-LN
(3) SE-XLN/XE-XLN/HSS-SN/HSS-XLN/HSE-XLN
Intake
(4) Option is not define for size 250 option SE-SN/SE-LN/SE-XLN/HSS-LN/HSS-XLN
(5) Max Speed - range is 60% to 100% of max speed
Measurement conditions:
(6) SE-SN/SE-LN/SE-XLN/HSS-SN/HSS-LN/HSS-XLN
(7) HE-SN/HE-LN/XE-SN/XE-LN/XE-XLN/HSE-SN/HSE-LN/HSE-XLN
Measurements taken at the horizontal air intake.
Fan
Unit
speed
1
FWD 08
2
3
1
FWD 10
2
3
1
FWD 12
2
3
1
FWD 14
2
3
1
FWD 20
2
3
RLC-SVX19E-GB
UNT-PRC002-GB
RTAF
250 (4)
#
N/A
#
(L/s)
40.2
(kPa)
96
(kW)
11.0
(A)
20.5
kW
1.32
A
3.30
(kg)
N/A
Power level in dB(A), per Hz frequency band
(kg)
1348
125
250
500
(L)
N/A
55
50
42
(L)
111
57
54
47
(L)
N/A
58
57
50
57
51
45
(L)
475
58
54
48
(m)
N/A
60
58
50
(m)
1.125
57
51
45
58
54
48
60
58
50
56
62
50
61
66
55
63
69
58
57
63
51
61
66
55
63
69
58
Power level in dB(A), per Hz frequency band
125
250
500
56
55
55
63
62
60
66
65
63
62
58
55
66
63
60
70
67
63
62
58
55
66
63
60
70
67
63
66
65
65
73
72
69
78
76
73
68
72
64
76
76
68
78
79
71
RTAF
RTAF
RTAF
280
310
350
8
10
10
8
8
10
10
44.8
49.8
55.9
78
85
80
11.0
11.0
11.0
20.5
20.5
20.5
1.32
1.32
1.44
3.30
3.30
3.60
1422
1551
1675
1419
1547
1675
1000
2000
132
132
182
37
37
132
132
182
40
30
496
560
575
42
32
42
34
493
556
575
45
38
1.125
1.125
1.125
48
40
1.125
/
1.125
42
34
45
38
48
40
48
39
53
47
56
50
49
40
53
47
56
50
1000
2000
53
46
60
53
62
56
58
51
62
56
65
59
58
51
62
56
65
59
65
57
71
64
75
69
64
56
71
65
74
69
Optional Free-Cooling
RTAF
RTAF
RTAF
380
410
415
10
12
N/A
10
12
12
61.6
66.8
68.0
87
94
98
11.0
11.0
11.0
20.5
20.5
20.5
1.44
1.44
1.44
3.60
3.60
3.60
1736
1775
N/A
Overall power
1736
1803
1803
4000
8000
182
182
N/A
31
30
182
182
182
38
40
589
635
N/A
40
43
33
28
589
639
639
39
35
1.125
1.125
N/A
42
39
/
/
/
33
28
39
35
42
39
38
36
46
45
50
49
39
37
46
45
50
49
Overall power
4000
8000
45
42
53
53
55
57
48
44
55
52
59
57
48
44
55
52
59
57
50
46
59
57
64
63
52
50
61
61
66
66
RTAF
450
N/A
12
72.2
109
11.0
20.5
1.44
3.60
N/A
1803
dB(A)
N/A
46
182
50
N/A
53
48
639
51
N/A
54
/
48
51
54
56
60
63
57
60
63
dB(A)
57
64
67
61
66
69
61
66
69
68
74
78
69
75
78
11