OPERATING PROCEDURE
(8) Remove 2 electrical parts box fixing screws (4 × 10) and
detach the electrical parts box by pulling it upward. The
electrical parts box is fixed with 2 hooks on the left and 1
hook on the right.
Photo 5 (VKA type)
4. Disassembling the electrical parts box (VKA type)
(1) Disconnect all the connectors on the controller circuit board.
(2) Remove the screws 1, that fix the plate equipped with the
outdoor controller circuit board, and the electrical parts box.
(See Photo 7)
(3) Remove the controller circuit board. (See Photo 7)
(4) Disconnect the connectors of reactor on the bottom plate
of the electrical parts box. (See Photo 8)
(5) Remove 2 screws 2 on the rear plate of the electrical parts
box. (See Photo 8)
(6) Remove the reactor(s). (See Photo 8)
Note: 1. When reassembling the electrical parts box, make
sure that the wirings are correct.
2. When exchanging the reactor, make sure to
exchange all the 3 reactors.
Photo 8
Screws 2
OCH671
Electrical
parts box
Electrical
parts box
fixing screw
Reactor
Connectors
of Reactor
Reactor
Connectors
of Reactor
Connectors
of Reactor
Electrical
parts box
Reactor
PHOTOS/FIGURES
Photo 6 (YKA type)
Photo 7
104
Electrical
parts box
Electrical parts
box fixing
screw
Electrical
Controller circuit board
parts box
(C.B)
Screws
Power circuit board
(behind the C.B)
1

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents