Specifications - Rinnai RL75E Operation And Installation Manual

Outdoor tankless water heater
Hide thumbs Also See for RL75E:
Table of Contents

Advertisement

Available languages

Available languages

Model
Minimum Gas Consumption Btu/h
Maximum Gas Consumption Btu/h
Hot water capacity (Min - Max) *
Hot water capacity (45°F rise)
Default Temperature Setting (no controller)
Temperature Controller Default Setting
Maximum Temp Setting (commercial **)
Maximum Temp Setting (residential)
see Temperature Ranges for more information
Minimum Temperature Setting
Weight
Efficiency
Noise level
Normal
Electrical
Standby
Consumption
Anti-frost Protection
By-Pass Control
Natural Gas
Minimum Gas
Supply
Propane
Natural Gas
Maximum Gas
Supply
Propane
Type of Appliance
Operation
Approved Gas Type
Connections
Ignition System
Electric Connections
Water Temperature Control
Water Supply Pressure
Maximum Water Supply Pressure
Temperature Control Cable
Energy Star Qualified
Certified for installation in manufactured
(mobile) homes
* Minimum flow may vary slightly depending on the temperature setting and the inlet water temperature.
** for commercial and hydronic applications requiring higher temperatures
Rinnai is continually updating and improving products. Therefore, specifications are subject to change without prior notice.
The maximum inlet gas pressure must not exceed the value specified by the manufacturer. The minimum value listed is for
the purpose of input adjustment.

Specifications

RL75e
RL94e
9,900 (NG)
10,300 (LPG)
180,000
199,000
0.4 - 7.5 GPM
0.4 - 9.4 GPM
(1.5 - 28.5 L/min)
(1.5 - 35.5 L/min)
6.6 GPM
7.1 GPM
(25.1 L/min)
(27.0 L/min)
160º F (71º C)
Selectable at 120º F (49º C) or
at 140º F (60º C)
51 lb (23 kg)
Energy Factor: 0.82
Energy Factor: 0.82
44 W
104 W
Fixed
Temperature controlled continuous flow gas hot water system.
With or without temperature controls, mounted in kitchen, bathroom, etc.
Natural Gas or Propane - Ensure unit matches gas type supplied at the installation location.
Gas Supply: 3/4" MNPT, Cold Water Inlet: 3/4" MNPT, Hot Water Outlet: 3/4" MNPT
Appliance: AC 120 Volts, 60Hz. Temperature Control: DC 12 Volts (Digital)
Simulation Feedforward and Feedback.
Minimum Water Pressure: 20 PSI (Recommended 30-80 PSI for maximum performance)
Non-Polarized Two Core Cable (Minimum 22 AWG)
Yes
Yes
VB Series Outdoor LS Manual
R98LSe
120º F (49º C)
104º F (40º C)
185º F (85º C)
98º F (37º C)
Thermal Efficiency: 83.0%
49 dB (A)
49 W
2 W
Electronic
5.0 inch W.C.
8.0 inch W.C.
10.5 inch W.C.
13.5 inch W.C.
Direct Electronic Ignition
150 PSI
Yes
No
Yes
No
R98LSe-ASME
19,000
237,000
0.6 - 9.8 GPM
(2.3 - 37 L/min)
8.5 GPM
(32 L/min)
140º F (60º C)
55 lb (25 kg)
72 W
116 W
No
No
3

Hide quick links: