Type of Appliance
Rinnai Model Number
Operation
Minimum/Maximum Gas Rate (Input)
Electrical
Electrical Consumption
Ignition System
Hot Water Capacity
Temperature
Temperature (without remote)
Approved Gas Types
Installation
Energy Factor
Thermal Efficiency
Service Connections
Water Flow Control
Minimum/Maximum Water Supply Pressure
FLOW TABLE
© 2010 Rinnai Corporation
10.0
9.0
8.0
7.0
6.0
5.0
4.0
3.0
2.0
1.0
0.0
0
25
R94LSe VB SP
Temperature controlled, continuous flow, gas hot water system;
certified for installation in manufactured (mobile) homes
REU-VB2735WD-US
Forced combustion
9,900 - 199,000 BTU/h (Natural Gas)
10,300 - 199,000 BTU/h (Propane)
Appliance:
Controller:
Normal
Standby
Anti-frost protection
Direct electronic ignition
Minimum flow rate: 0.26 GPM
Minimum activation flow rate: 0.4 GPM
Maximum flow rate: 9.4 GPM (35° F rise)
98° - 120° F (factory default) Maximum temperature is selectable at
120° F or at 140° F; 98° - 185° F available with the MCC-91
controller for commercial and hydronic applications
120° F (factory default)
Natural or Propane (ensure unit matches gas type)
Outdoor only
Natural Gas: 0.82
Natural Gas: 83%
Gas supply: 3/4 inch MNPT
Hot water outlet: 3/4 inch MNPT
Water flow sensor, electronic water control device and fixed by-pass
20 - 150 PSI (recommended 30-80 PSI for maximum performance)
50
75
∆ T – Temperature Rise (°F)
8/2010
R94LSe (VB2735WD-US)
AC 120 Volts - 60 Hz
DC 12 Volts
49 watts
2 watts
104 watts
Propane: 0.82
Propane: 83%
Cold water inlet: 3/4 inch MNPT
100
125
150

Advertisement

loading

Summary of Contents for Rinnai REU-VB2735WD-US

  • Page 1 Thermal Efficiency Service Connections Water Flow Control Minimum/Maximum Water Supply Pressure 10.0 FLOW TABLE © 2010 Rinnai Corporation R94LSe (VB2735WD-US) Temperature controlled, continuous flow, gas hot water system; certified for installation in manufactured (mobile) homes REU-VB2735WD-US Forced combustion 9,900 - 199,000 BTU/h (Natural Gas)
  • Page 2 Local, state, provincial and federal codes must be adhered to prior to installation. DIMENSIONS WEIGHT: 51 LBS (23 KG) Rinnai Corporation • 103 International Drive • Peachtree City, GA 30269 • Toll-Free: 1-800-621-9419 • Fax: 678-364-8643 • www.rinnai.us Simulation feed forward and feedback MC-91-1US (included)