Appendix: Specifications - Visonic CLIP PG2 Installation Instructions Manual

Powerg wireless, curtain, pir motion detector
Table of Contents

Advertisement

Warning! To comply with FCC and IC RF exposure compliance requirements, the device should be located at a distance of at least 20 cm from all
persons during normal operation. The antennas used for this product must not be co- located or operated in conjunction with any other antenna or
transmitter.
This device complies with Part 15 of the FCC Rules and RSS- 210 of Industry and Science Canada. Operation is subject to the following two
conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that
may cause undesired operation.
Le present appareil est conforme aux CNR d'Industrie Canada applicables aux appareils radio exempts de licence. L'exploitation est autorisee aux
deux conditions suivantes :(1) l'appareil ne doit pas produire de brouillage, et (2) l'utilisateur de l'appareil doit accepter tout brouillage radioelectrique
subi, meme si le brouillage est susceptible d'en compromettre le fonctionnement.
W.E.E.E. Product Recycling Declaration
For information regarding the recycling of this product you must contact the company from which you orignially purchased it. If you are discarding this product and not returning it for repair then
you must ensure that it is returned as identified by your supplier. This product is not to be thrown away with everyday waste.
Directive 2002/96/EC Waste Electrical and Electronic Equipment.

APPENDIX: SPECIFICATIONS

OPTICAL
Detector Type
Number of Curtain Beams
Mounting Positions
Range Settings
ELECTRICAL
Internal Battery
Nominal Battery Capacity
Low Battery Threshold
Battery Life (for typical use)
FUNCTIONAL
Visual indications:
Alarm Period
WIRELESS
Frequency Band (MHz)
Maximum Tx Power
Communication Protocol
Supervision
Tamper Alert
MOUNTING
Height
Installation Options
ACCESSORIES
ENVIRONMENTAL
RFI Protection
Operating Temperatures
Storage Temperatures
Humidity
PHYSICAL
Size (H x W x D)
Weight (with battery)
Color
PATENTS
D-303370 CLIP PG2 Installation Instructions
Dual element low-noise pyroelectric sensor
2
See
Figures 2 through 6
Maximum (6 m), Medium (4 m) and Minimum (1.2 – 2m) (remotely selected)
3V Lithium battery, type CR-123A or equivalent
Notes:
1. Use only the above battery type.
2. For UL installations use Gold Peak (GP) or Panasonic CR123A only.
1450 mA/h
2.45 V
7 years
Red LED lights for about 2 seconds upon motion detection in the walk test mode and for about 0.2
sec. for tamper messages.
Red LED blinks during the power-up stabilization period (approx. 1 min), or after restoring the
cover (by pressing the tamper switch).
Red LED does not light upon transmission of supervision messages.
Approx. 2 seconds
Europe and rest of world: 433-434, 868-869 USA: 912-919
10 dBm @ 433 MHz, 14 dBm @ 868 Mhz
PowerG
Signaling at 4-min. intervals
Reported when a tamper event occurs and in any subsequent message, until the tamper switch is
restored
1.8 - 2.4 m (6 - 8 ft).
See
Figures 9 through 13
BR-1: Surface mounted swivel bracket, adjustable 30° down and 45° left/45° right.
BR-2: BR-1 with a corner adapter
BR-3: BR-1 with a ceiling adapter
Note: UL did not evaluate the product with the use of the BR brackets
>20 V/m up to 2000 MHz, excluding inband frequencies
-10°C to 50°C (14°F to 122°F) indoor
Note: UL tested 0°C to 49°C
-20°C to 60°C (-4°F to 140°F)
Average relative humidity of approximate 75% non-condensing. For 30 days per year relative
humidity may vary between 85 % and 95 % non-condensing.
Note: For UL installations, relative humidity is 85%.
105 x 35 x 30 mm (4-1/8 x 1-3/8 x 1-3/16")
60 g (2.1 oz).
White
U.S. Patents 5,693,943 • 6,211,522 • D445,709 (another patent pending)