5. Specifications

GENERAL
Detector Type
One pyroelectric sensor operating in a dual separated configuration
OPTICAL
Lens Data
Fresneltype lens.
Number of beams: 72
Max. coverage
Ø10 m/360° at the maximum installation height of 4 m
ELECTRICAL
Power Supply: Type C
Internal Battery
3V Lithium battery, type CR-123A. For UL installations, use Panasonic and GP only
Nominal Battery Capacity: 1450 mAh
Battery Life (typical use)
Minimum 1 year. For typicaluse (security mode), 5 years (not verified by UL).
Low Battery Threshold: 2.4 V
NOTE: Inability to connect with wireless network, or wireless link qualityno higher than 20% may significantly reduce the expected battery life.
Battery Power Test
Performed immediately upon battery insertion and periodically after every several hours.
The power supply is type C in accordance with EN 50131-6 Documentation – Clause 6.
Current Consumption
20 μA average quiescent , maximum 150 mA (during transmission)
FUNCTIONAL
Alarm Period: 2 seconds
WIRELESS
Frequency
Europe and rest of world: 433- 434 MHz, 868- 869 MHz USA: 912- 919 MHz
NOTE: Only devices in frequency band 915 MHz are UL/ULC listed.
Max Tx Power
10 dBm @ 433MHz, 14 dBm @ 868MHz
Communication Protocol: PowerG BW
Supervision: Signaling at 256 s intervals
Tamper Alert
Reported when a tamper event occurs and in any subsequent message, until the tamper switch is restored.
MOUNTING
Height: 2 m to 4 m
Installation Options: Ceiling surface
D-307080 MP- 862 Installation Instructions
Figure 7. Beam distribution at 4 m
Figure 8. Beam distribution at 2.7 m