8. SPECIFICATIONS

GENERAL
Detector Type
Dual element low-noise pyroelectric sensor
OPTICAL
Fresnel and cylinder type lens with optical attenuation
(PET mask) in the lower pattern part of the lens.
Lens Data
Number of beams/curtains: 27 Fresnel far (54 sensitivity
"beams"), 18 Cylinder mid, 10 Cylinder close.
Max. coverage
12 x 12 m (39 x 39 ft) / 90°
Pet Immunity
Up to 38 kg (85 lb)
ELECTRICAL
Power Supply
Type C.
Internal Battery
3V Lithium battery, type CR-123A. For UL installations, use Panasonic and GP only
Nominal Battery
1450 mAh
Capacity
Battery Life (typical use) Minimum 1 year. For typical use, 6 to 8 years (not verified by UL).
Low Battery Threshold
2.4 V
Inability to connect with wireless network, or wireless link quality no higher than 20% may significantly reduce the expected
Note:
battery life
Performed immediately upon battery insertion and periodically after every several hours.
Battery Power Test
The power supply is type C in accordance with EN 50131-6 Documentation – Clause 6.
Current Consumption
10μA average quiescent , maximum 40mA (during transmission)
FUNCTIONALITY
True Motion Event
2 remote selections at panel – LOW, HIGH
Verification
Alarm Period
2 seconds
LED Switch
LED Enable (red LED lights for 2 sec. upon alarm detection)
WIRELESS
Europe and rest of world: 433-434 MHz, 868-869 MHz USA: 912-919 MHz
Frequency
Note: Only devices in frequency band 915 MHz are UL/ULC listed
Max Tx Power
<10 dBm (433-434), <14dBm (868-869)
Communication Protocol PowerG
Supervision
Signaling at 4-min. intervals
Tamper Alert
Reported when a tamper event occurs and in any subsequent message, until the tamper switch is restored
MOUNTING
1.8-2.4 m (6 - 8 ft.). For pet rejection, the optimal height is 2.1 m (7 ft.)
Height
At 2.4m (7.87 ft.) height installation, remove pet mask as pet immunity is not supported.
Installation Options
Surface or corner
ENVIRONMENTAL
RF Immunity
20 V/m up to 1000 MHz, 10 V/m up to 2700 MHz
Operating Temperatures -10°C to 50°C (14°F to 122°F). Note: UL verified operation range 0°C to 49°C only.