4 Mounting and Wiring
Size and conductor pairs: 0.5 mm × 4 Pairs (for 100BASE-TX)
Part name
Cables
RJ45 Connectors
Attaching the Connectors to the Cable and Pin Assignments
Use straight wiring to attach the connectors to the communications cable.
Pin No.
1
2
3
4
5
6
7
8
Hood
*1. Connect the cable shield to the connector hood at both ends of the cable.
*2. There are two connection methods for Ethernet: T568A and T568B. The T568A connection method is shown
above, but the T568B connection method can also be used.
Connector Specifications
Item
Electrical characteristics
Connector structure
Pin Assignments
Physical layer standards: 100BASE-TX
8
1
4 - 14
Manufacturer
Fujikura Ltd.
Panduit Corporation
Wire color
White-Green
Green
White-Orange
Blue
White-Blue
Orange
White-Brown
Brown
Shield
Conforms to IEEE 802.3 standards.
RJ45 8-pin modular connector (Conforms to ISO 8877.)
Pin No.
Signal name
1
Transmission data +
2
Transmission data −
3
Reception data +
4
Not used.
5
Not used.
6
Reception data −
7
Not used.
8
Not used.
CK3E-series Programmable Multi-Axis Controller Hardware User's Manual (I610)
Model
F-LINK-E 0.5 mm × 4
Pairs
MPS588
Wire color
White-Green
White-Orange
White-Blue
White-Brown
Specification
Abbrevia-
Signal direc-
tion
TD+
TD-
RD+
---
---
RD-
---
---
Contact
Planning Department, Kanetsu
Co., Ltd.
Panduit Corporation
Osaka office, Japan branch
Pin No.
1
Green
2
3
Blue
4
5
Orange
6
7
Brown
8
Shield
Hood
tion
Output
Output
Input
---
---
Input
---
---