Diagnostic Tests; Test Descriptions - Philips VL550 User Manual

Series 50 wash luminaires
Table of Contents

Advertisement

4
M
S
: S
T
ENU
YSTEM
ELF
ESTS
Movement Disable
The Movement option allows pan and tilt to be disabled so that the luminaire can be placed in any
position for testing without movement occurring. In order to regain full control of the luminaire,
Movement will need to be enabled after testing.
Note: When using the Movement option, pan and tilt will be disabled for all the luminaires that are
linked.
To set movement option:
Step 1. Press [Menu].
Step 2. Press [Up] / [Down] arrows until Config appears. Press [Enter].
Step 3. Press [Up] / [Down] arrows until Pan/Tilt appears. Press [Enter].
Step 4. Movement will be displayed. Press [Enter].
Step 5. Use [Up] / [Down] arrows to select Enable or Disable. Press [Enter] to select.

Diagnostic Tests

The following diagnostic tests are available in the test menu.

Test Descriptions

All Seq................. Tests all functions in sequential order.
Pan/Tilt ................ Tests different pan and tilt movements.
Pan...................... Tests different pan movements.
Tilt ....................... Tests different tilt movements.
Dimmer................ Tests different dimmer operation.
Diffuser................ Tests diffuser movement.
Cyan.................... Tests Cyan color wheel movements.
Yellow .................. Tests Yellow color wheel movements.
Magenta .............. Tests Magenta color wheel movements.
Encoder............... Disables pan and tilt and displays encoder value.
Fan ...................... Tests fan level (speed 1 to 7, 7 is fastest).
Temperature ........ Displays LVS or MCB temperatures (in
C).
o
02.96 83.000 1 0
16 No vemb er 2010
53

Advertisement