Power and Data Cabling Requirements

Power

The luminaire requires standard AC power distribution from 100-240 VAC, 50/60 Hz. Three amps to
twelve amps will be required depending on the AC supply voltage and product model.
Depending on the application, the luminaire's AC input cable may require a different connector. If
required, install a new connector meeting your requirements using the following wire color code
reference:
WARNING: DO NOT connect to three-phase service in countries with 240 volt power.
For single-phase power at 100 to 240 volts RMS:
For three-phase power at 208 volts RMS:
WARNING: It is not recommended to power any VARI❋LITE
'NONDIM' mode. Dimmer and non-dim modules are not suitable sources of power because their
output modifies the AC wave form. This may work for a short time, but will eventually result in power
problems, luminaire mis-operation and/or failure. Only the lamp on Series 550 Wash Luminaires,
WITHOUT an on-board dimmer (only at the lamp input power connector), can be controlled through
an external dimmer circuit. The luminaire power must not be connected to a dimmer.
10
L
U
'
ASH
UMINAIRE
SER
S
Wire*
Green/Yellow
Blue
Brown
Connection
AC Neutral
AC Line
Ground (Earth)
Connection
Phase 1
Phase 2
Ground (Earth)
16 No vemb er 2010
M
ANUAL
Connection
AC Ground
AC Neutral
AC Line
Pin
X
X
Y
G
Pin
X
X
Y
G
luminaire from a dimmer - even in
®
* International (Harmonized) Standard
G
Y
G
Y
02 .9 683.00 01 0