Temperature Limits

5. The Digital Display will show the stored default High ("Hi") Temperature Limit by
alternating to show "Hi" and the stored limit. Choose one of the following:
Press and release the Program Key ( ) to keep the stored High
Temperature Limit.
Adjust the stored High Temperature Limit using the keypad. (
be adjusted below the Low Temperature Limit.
Press and release the Program Key ( ) to proceed to the next step.
6. The Digital Display now shows the stored default Low ("Lo") Temperature Limit with
the display alternating to show "Lo" and the stored limit. Choose one of the
following:
Press and release the Program Key ( ) to keep the stored Low
Temperature Limit.
Adjust the stored Lo Temperature Limit using the keypad. (
Press and release the Program Key ( ) to proceed to the next step.
The allowable temperature range of the ADS200 is between 177° C (350° F) and 454° C (850° F). The Low
Temperature Limit cannot be adjusted higher than the High Temperature Limit. These limits control how high or
low the Set Temperature can be adjusted to during normal operation.

Automatic Setback Timer

What is Temperature Setback? To preserve tip life and save energy, the system can be programmed to
automatically set its Tip Temperature to a lower set point (adjustable during step 14) after a selectable period of
inactivity (factory setting of 30 minutes). As received from the factory, this feature is enabled at 30 minutes and
a temperature of 177° C (350° F). There are 3 ways to exit Temperature Setback; pressing the Scroll Up or Scroll
Down keys (
), flipping the power switch off then on again, or holding the tip against a damp sponge. Upon
exit of the Temperature Setback, the unit will resume normal operations and the handpiece heat back up to the
Set Temperature.
7. The Digital Display now shows the stored Automatic Setback time as "S-X" (x=0
thru 9). Time is shown as tens of minutes (e.g., "S-3" equals 30 minutes). A display
of "S-0" indicates that Setback is disabled. Choose one of the following:
Press and release the Program Key ( ) to keep the currently stored
Temperature Setback time.
Adjust the stored Temperature Setback value using keypad. (
Press and release the Program Key ( ) to proceed to the next step.