SetBack Temperature

11. The Digital Display will now alternate between "Sbt" and a temperature. This is the temperature that the
system will go to anytime the system goes into SetBack, either from the built-in
timer or from the Instant SetBack Tool Stand.
Press and release the Program Key ( ) to keep the currently stored
Temperature or;
Adjust temperature value using the keypad. (
between 150° C (300° F) and 230° C (450° F).
Press and release the Program Key ( ) proceed to the next step.

Temperature Match Mode

12. The Digital Display will read "0Cx" with "x" being a number from 0 to 3, indicating which Temperature
Match Mode the system is in. Please refer to the Temperature Match Mode manual at our website
https://paceworldwide.com/ads200-temperature-match-mode-manual.

Exiting Set-Up Mode

13. The LED Display now reads "End". The Set-Up Mode procedure is now complete.
Choose one of the following steps:
Press and release the Scroll Up Key ( ) to save the changes, exit the Set-Up
Menu and return to normal operation.
Press and release the Scroll Down Key ( ) to return to the start of the Set-Up
Menu without saving any changes. Go back to step 3, Password Entry.

Corrective Maintenance

Digital Display Message Codes

Listed below are message codes, which, may be shown on the LED Display if a mistake were to be made by the
operator (e.g., wrong Password entry) or if the system has malfunctioned.
LED Display Message Description
©2018 PACE Inc., Vass, North Carolina, All Rights Reserved
The incorrect password has been entered. The displayed message
will time out after 6 seconds and revert to normal operation. Enter
the correct password.
"Check Handpiece" A handpiece is not connected to the Power
Receptacle or is faulty, or the Tip-Heater Cartridge is not properly
inserted or faulty.
"Over Current Error" The Tip-Heater Cartridge circuit is shorted or
the handpiece has failed. Replace the Tip-Heater Cartridge.