DSC PC5020 Installation Manual page 9

Power864 security system
Hide thumbs Also See for PC5020:
Table of Contents

Advertisement

• PC5921 EXT Door Box Audio Station can be used in conjunc-
tion with the PC5936 Audio Interface Module.
• PC5921 EXT/R Door Box Audio Station can be used in con-
junction with the PC5936 Audio Interface Module. The Door
Box contains a relay so the normal door bell can be used
instead of the internal one generated by the PC5936 Audio
Interface Modules.
PC5400 Printer Module
This PC5400 Printer Module will allow the panel to print out all
events that occur on the system to any serial printer. All events
will be printed with the Partition, time, date and the event that
occurred. (Refer to the PC5400 Installation Manual for details.)
NOTE: Please see the PC5020 Module Compatibility Chart on the
back cover for compatible versions.
LINKS1000 Cellular Communicator
The LINKS1000 Cellular Communicator provides an efficient,
cost-effective method for adding cellular back up. The unit comes
in its own cabinet with antenna and requires a separate battery
and transformer (See Links1000 Cellular Communicator in Section
5).
Alternate Communicators
Refer to the associated installation manual for LINKS2X50 and
Skyroute™ programming details.
Downlook Support: PC5108L and DLM-4 v1.0L
The PC5108L will expand the control panel's zone capability by
adding eight fully programmable zone inputs. The module will
also act as an interface between the DLM-4L v1.0 Video Transmis-
sion module and the PC5020 control panel. The PC5108L is also
an 8-camera video switcher.
For more information on either module, see their respective
Installation Manuals.
NOTE: Please see the PC5020 Module Compatibility Chart on the
back cover for compatible versions.
NOTE: Do not mix PC5108L v1.x and lower modules with PC5108
v2.0 and higher modules on the same system.
PC5700 Fire Module
This is a zone expansion module with four general purpose zone
inputs, two Class A supervisory waterflow zone inputs, ground
fault detection and dual-supervised telephone line inputs.
PC5720 Fire Module
This is a zone expansion fire module that can be used for ULC-
listed non-residential fire applications. The PC5720 can also be
used as an interface between the control panel and either a serial
printer or a DVACS communications network.
NOTE: Do not use the PC5700 and PC5720 v1.x and lower mod-
ules with PC5108 v2.0 and higher modules on the same system.
Cabinets
Several different cabinets are available for the PC5020 modules.
They are as follows:
• PC4050 cabinet to house the PC5936/5937 and
Escort5580TC together. Dimensions 305mm x 376mm x
125mm / 12" x 14.8" x 4.9" approximately.
I n t r o d u c t i o n : 1 . 4 A d d i t i o n a l D e v i c e s
• PC4050CR alternate main control cabinet (Fire) for the
PC5020 main panel. Dimensions 305mm x 376mm x 125mm /
12.0" x 14.8" x 4.9" approximately.
• PC5002C cabinet to house the PC5204 Power Supply Output
Module. Dimensions 213mm x 235mm x 78mm / 8.4" x 9.25"
x 3" approximately.
• PC5003C main control cabinet for the PC5020 main panel.
Dimensions 222mm x 298mm x 78mm / 11.3" x 11.7" x 3.0"
approximately.
• PC5004C cabinet to house the Escort5580 Module and
PC5400 Printer Module. Dimensions 229mm x 178mm x
66mm / 9" x 7" x 2.6" approximately.
• PC5001C cabinet to house the PC5108 Zone Expander Mod-
ule and the PC5208 Eight Low Current Output Module.
Dimensions 153mm x 122mm x 38mm / 6" x 4.8" x 1.5"
approximately.
• PC5001CP plastic cabinet to house the PC5108 Zone
Expander Module and the PC5208 Eight Low Current Output
Module. Dimensions 146mm x 105mm x 25.5mm / 5.75" x
4.2" x 1" approximately.
• Multi-3 cabinet to house the PC5936/PC5937. Dimensions
287mm x 298mm x 78mm / 11.3" x 11.7" x 3.0" approxi-
mately.
• HS-CAB100 structured wiring cabinet for PC5020 main panel.
Dimensions 362mm x 229mm x 102mm / 14.25" x 9" x 4"
with a wire raceway positioned on the right side of the cabi-
net. The cover is 389mm x 254mm / 15.3" x 10".
• HS-CAB200 structured wiring cabinet for PC5020 main panel.
Dimensions are 362mm x 362mm x 102mm / 14.25" x 14.25"
x 4" with a wire raceway in the center of the cabinet. The
cover is 389mm x 389mm / 15.3" x 15.3".
• HS-CAB300 structured wiring cabinet for PC5020 main panel.
Dimensions 724mm x 362mm x 102mm / 28.5" x 14.25" x 4"
with a wire raceway in the center of the cabinet. The cover is
752mm x 387mm / 29.6" x 15.3".
Backplates
There are two different backplates available for keypads to mount
an Audio Station next to a keypad:
PC55BP1 Backplate
Use this backplate when mounting an
Audio Station next to a keypad. Dimen-
sions 208mm x 115mm x 18mm / 8.2"
x 4.5" x 0.25" approximately.
PC55BP2 Backplate
Use this backplate when mounting an
Audio Station next to a keypad. In addi-
tion the backplate will allow you to
mount a PC5108 Zone Expander Mod-
ule or the PC5208 Eight Low Current
Output Module. Dimensions 208mm x
115mm x 18mm / 8.2" x 4.5" x 0.7"
approximately.
3

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents