Section #
Reporting Code
[344]
Special Opening
[345]-[346]
Battery Trouble/Rest.
[345]-[346]
AC Line Trouble/Rest.
[345]-[346]
Bell Circuit Trouble/Rest.
[345]-[346]
Fire Trouble/Rest.
[345]-[346]
Auxiliary Power Trouble/Rest. Aux voltage supply trouble/restoral
[345]
TLM Failure
[346]
TLM Restore
[345]-[346]
Gen System Trouble/Rest.
[345]-[346]
Gen System Supervisory
Trouble/Rest.
[347]
Phone# 1 or 2 FTC Restoral
[347]
Event Buffer is 75% Full
[347]
DLS Lead In
[347]
DLS Lead Out
[347]
Zone Fault/Rest.
[347]
Delinquency
[347]
Wireless Device Low Battery
Trouble/Rest.
[348]
Walk Test End
[348]
Walk Test Begin
[348]
Periodic Test with Trouble
[348]
Periodic Test
[348]
System Test
[348]
LINKS1000 Test
[349]
PC5700 Ground Fault Trou-
ble/Restore
[349]
PC5700 TLM Line 1 Trouble/
Restore
[349]
PC5700 TLM Line 2 Trouble/
Restore
*
A/R = alarms/restorals; T/R = tampers/restorals; O/C = openings/closings; MA/R = miscellaneous alarms/restorals; T = test transmissions
**
UU = user number (user01-42); ZZ = zone number (01-64)
***
Use the "Fail to close" event code [(4)54] to report closing or activity delinquency. Ensure the central station is aware that this code is used.
****
Zones are identified, panic pendants, wireless keys, and handheld keypads are not.
Table2: Contact ID Zone Alarm/Restoral Event
Codes (as per ADEMCO):
Program any of these codes for zone alarms/restorals when using
the standard (non-automatic) Contact ID reporting format.
Medical Alarms
(1)AA Medical
(1)A1 Pendant Transmitter
(1)A2 Fail to Report In
Fire Alarms
(1)1A Fire Alarm
(1)11 Smoke
(1)12 Combustion
(1)13 Water Flow
(1)14 Heat
56
Code Sent When...
Opening (disarming) using one of the following methods:
keyswitch, maintenance code, DLS software, wireless key
PC5020 battery is low/battery restored
AC power to control panel is disconnected or interrupted/
AC power restored (Both codes follow AC Failure Comm.
Delay.)
Open or short circuit detected across bell terminals/bell cir-
cuit restored
Trouble occurs/restores on a fire zone
Telephone line monitoring trouble (sent via LINKS1000. Do
not program if LINKS1000 not used)
Telephone line restored
"Service Required" trouble occurs (view troubles using
[*][2])/trouble restored
Control panel loses/restores communications with mod-
ule(s) connected to the Keybus
Control panel has restored communications to central sta-
tion on Phone# 1 or 2 (after FTC)
Event buffer is almost full since last upload
Downloading session start
Downloading session complete
One or more zones have faults/restored
Programmed amount of time (days or hours) for delin-
quency has expired without zone activity, or without system
being armed
Wireless zones, panic pendants, handheld keypads, wireless
keys have low battery/all low batteries restored
End of test
Beginning of test
Periodic system test transmission with trouble
Periodic system test transmission
[*][6] bell/communications test
LINKS1000 test transmission
Ground/Fault/Trouble occurs on the PC5700
TLM Trouble /Restore occurs on the PC5700
TLM Trouble /Restore occurs on the PC5700
(1)34 Entry / Exit
(1)35 Day / Night
(1)36 Outdoor
(1)37 Tamper
(1)38 Near Alarm
General Alarms
(1)4A General Alarm
(1)43 Exp. module failure
(1)44 Sensor tamper
(1)45 Module Tamper
Dialer
Direction*
O/C
MA/R
MA/R
MA/R
MA/R
MA/R
MA/R
MA/R
MA/R
MA/R
MA/R
MA/R
MA/R
MA/R
MA/R
MA/R
MA/R
T
T
T
T
T
T
MA/R
MA/R
MA/R
(1)15 Pull Station
(1)16 Duct
(1)17 Flame
(1)18 Near Alarm
Panic Alarms
(1)2A Panic
(1)21 Duress
(1)22 Silent
(1)23 Audible
Burglar Alarms
(1)3A Burglary
(1)31 Perimeter
(1)32 Interior
(1)33 24 Hour
Automatic
SIA Auto Rep
Contact ID
Codes**
Codes
(4) AA
OP-00
(3) A2
YT-00/YR-00
(3) A1
AT-00/AR-00
(3) 21
YA-99/YH-99
(3) 73
FT-00/FJ-00
(3) AA
YP-00/YQ-00
(3) 51
LT-00
(3) 51
LR-00
(3) AA
YX-00/YZ-00
(3) 33
ET-00/ER-00
(3) 54
YK-00
(6) 23
JL-00
(4) 11
RB-00
(4) 12
RS-00
(3) 72
UT-ZZ/UJ-ZZ
(4) 54***
CD-00
(3) 84
XT-00/XR-00
XT-ZZ/XR-ZZ****
(6) A7
TS-00
(6) A7
TE-00
(6) A8
RP-01
(6) A2
RP-00
(6) A1
RX-00
(6) A3
TX-00
(3) 1A
US-00
(3) 51
LT-XX
(3) 52
LR-XX
(1)4A Cross Zone Police Code
24 Hour Non-Burglary
(1)5A 24 Hour non-Burg
(1)51 Gas detected
(1)52 Refrigeration
(1)53 Loss of Heat
(1)54 Water Leakage
(1)55 Foil Break
(1)56 Day Trouble
(1)57 Low bottled Gas level
(1)58 High Temp
(1)59 Low Temp
(1)61 Loss of Air Flow