When Installer Lockout Disable is selected the panel will
restore all programming to factory defaults if a hardware or soft-
ware default is performed on the main control panel.
To enable Installer Lockout perform the following:
1. Enter Installer Programming.
2. To enable Installer Lockout, enter section [990]
3. Enter the Installer Code.
4. Enter section [990] again.
[991][Installer Code] - Installer Lockout Disable
This disables the Installer Lockout feature described above.
To disable Installer Lockout perform the following:
1. Enter Installer Programming.
2. To disable Installer Lockout, enter section [991].
3. Enter the Installer Code.
4. Enter section [991] again.
[993]-[999] FACTORY DEFAULTS
On occasion it may be necessary to default the main control
panel or one of the modules that can be connected. There are
several different defaults available including defaulting the main
control panel, Escort5580 module, PC5132 Wireless Expander
Module, PC5400 Printer module and LINKS2X50 module.
NOTE: Defaulting the main panel does not default the keypads.
Refer to the Programming Worksheets Appendices A and B for
instructions for defaulting LCD5500Z and LCD5501Z keypads.
PC55XXZ LED keypads must be manually reprogrammed in pro-
gramming section [000].
Factory Default Main Panel (Hardware)
1. Remove AC and battery from the panel.
2. Remove all wires from the Zone 1 and PGM1 terminals.
3. With a piece of wire short the Zone 1 terminal to the PGM1
terminal.
4. Apply AC power to the main panel.
5. When Zone Light 1 is lit on the keypad the default is com-
plete.
6. Remove AC power from the control
7. Reconnect all original wiring and power up the control.
NOTE: AC power must be used to power the panel. The panel
will not default if the battery is used.
Factory Default Main Panel (Software) and other
Modules
1. Enter Installer Programming.
2. Enter the appropriate programming section [99X].
3. Enter the Installer Code.
4. Enter the appropriate programming section [99X] again.
The panel will take a few seconds to reset. When the keypad is
operational, the default is complete.
[993][Installer Code] - Restore Alternate Comm. Fac-
tory Default Programming
When this section is successfully entered, all programming in the
Alternate Communicator (LINKS2150, LINKS2450, LINKS3000, or
PC5400 DVACS Module) will be returned to the factory defaults.
[995][Installer Code] - Restore ESCORT 5580 Factory
Default Programming
When this section is successfully entered, all programming in the
ESCORT5580 Module will be returned to the factory defaults.
54
[996][Installer Code] - Restore PC5132 Wireless Fac-
tory Default Programming
When this section is successfully entered, all programming in the
PC5132 Wireless Expansion Module will be returned to the fac-
tory defaults.
[997][Installer Code] - Restore PC5400 Factory Default
Programming
When this section is successfully entered, all programming in the
PC5400 Serial Module will be returned to the factory defaults.
[998][Installer Code] - Restore PC59XX Factory
Default Programming
When this section is successfully entered, all programming in the
PC59XX Audio Matrix Module will be returned to the factory
defaults.
[999][Installer Code] - Restore Factory Default Pro-
gramming
When this section is successfully entered, all programming in the
PC5020 will be returned to the factory defaults. The program-
ming for the ESCORT, PC5132, PC5400 and PC59XX modules
will not be defaulted. When this command is executed, the
Module Supervision Field will be reset.