DSC PC5020 Installation Manual page 23

Power864 security system
Hide thumbs Also See for PC5020:
Table of Contents

Advertisement

the partition when the exit delay expires (see section [*] [9]
Arming Without Entry Delay on page 16).
[06] - [*]+[4] Door Chime On/Off
This function key provides the user a simple method for turning
the Door Chime feature on and off (see section [*] [4] Door
Chime On/Off on page 15).
[07] - [*]+[6]...[4] System Test
This function key provides the user with a simple method for
testing the system (see section [*] [6] User Functions on page
15). A valid Master Code is required to perform this command.
[08] - [*]+[1] Bypass Mode
This function key provides the user with a simple method for
entering the Bypass Mode. If a access code is required it must be
entered before bypassing can be performed (see section [*][1]
Zone Bypassing on page 14).
[09] - [*]+[2] Trouble Display
This function key provides the user with a simple method for
entering the Trouble Display Mode (see section [*][2] Trouble
Display on page 14).
[10] - [*]+[3] Alarm Memory
This function key provides the user with a simple method for
entering the Alarm Memory Display Mode (see section [*] [3]
Alarm Memory on page 15).
[11] - [*]+[5] Programming Access Codes
This function key provides the user with a simple method for
programming access codes. After this key is pressed a valid Sys-
tem Master or Supervisor Code will have to be entered before
the panel will allow programming to be performed (see section
[*] [5] Programming Access Codes on page 15).
[12] - [*]+[6] User Functions
This function key provides the user with a simple method for
programming User Functions. After this key is pressed a valid
System Master or Partition Master must be entered before the
panel will allow User Functions to be performed (see section [*]
[6] User Functions on page 15).
[13] - [*]+[7]+[1] Command Output Option 1
This function key provides the user with a simple method for
activating a PGM Output programmed as Command Output
Option 1 (See Section 5.8 Programmable Output Program-
ming PWS Sect 8). By default, after this key is pressed a valid
access code must be entered (see section [*] [7] Command Out-
put Functions on page 16).
[14] - [*]+[7]+[2] Smoke Detector Reset
This function key provides the user with a simple method for
activating a PGM output programmed as either option [03] Sen-
sor Reset or [20] Command Output option 2.
[15] - General Voice Prompt Help
This feature can only be programmed if both the Escort5580 and
the PC5936 Audio Matrix module are being used.
When the function key is pressed, the intercoms will perform a
Help page. The user must then press the Page/Answer button on
any intercom station to begin the help session with the Escort.
For more information, Refer to the PC5936 Installation Manual.
NOTE: While the voice prompt help is active, users will not be
able to disarm the system using Wireless Keys.
K e y p a d C o m m a n d s : 4 . 4 F u n c t i o n K e y s
[16] - [*]+[0] Quick Exit
Same as described in Function Keys - Section 3.5.
[17] - [*]+[1] Reactivate Stay/Away Zones
This function key provides the user with a simple method for
adding Stay/Away zones back into the system (see section [*][1]
Zone Bypassing on page 14).
[18] Identified Voice Prompt Help
This feature can only be programmed if the Escort5580 and the
PC5936 Audio Matrix module are being used.
When the function key is pressed, the Escort will begin a help
session from the intercom station programmed as closest to the
keypad. In order for this option to function, you must program
PC5936 Section [802], subsection [14] "Keypad Port Assign-
ments." For more information, Refer to the PC5936 Installation
Manuals.
NOTE: This function key cannot be programmed for PC55XXZ
LED keypads with software version 1.0.
NOTE: While the voice prompt help is active, users will not be
able to disarm the system using Wireless Keys.
[19] - [*]+[7]+[3] Command Output 3
[21] - [*]+[7]+[4] Command Output 4
Function Keys [19] and [21] provide the user with a simple
method of activating an output programmed as Command Out-
put Option 3 or 4.
[22] - Active Camera Monitor Selection
This function key is for use with the PC5108L Downlook Inter-
face/Camera Monitor Module. For instructions on the function
key use, see the PC5108L Installation Manual.
[23] - Bypass Recall
Pressing this function key will recall the last group of bypassed
zones. The function key will follow the Code Required for Bypass
option. If the option is enabled, a valid access code with the
Bypass attribute enabled must be entered after the function key
is pressed. For instructions on zone bypassing, see the Power864
Instruction Manual.
[24] - Recall Bypass Group
This function key will recall zones in the Bypass Group for the
partition. This group is programmed by the user in the [*][1]
Bypass menu. The function key will follow the Code Required for
Bypass option. If the option is enabled, a valid access code with
the Bypass attribute enabled must be entered after the function
key is pressed. For instructions on zone bypassing and program-
ming Bypass Groups, see the Power864 Instruction Manual.
[25]-[26] - For future use
[27] - Select Partition 3
[28] - Select Partition 4
[29] - Select Partition 5
[30] - Select Partition 6
[31] - Select Partition 7
[32] - Select Partition 8
These keys provide users with an easy way to select one of the
above partitions. For example, this is the same as pressing and
holding the [#] key, then pressing and holding the [3] key to
select Partition 3 (see section 4.5 Global and Partition Keypad
Operation on page 18).
17

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents