P48 Zero Clearance Direct Vent Gas Fireplace
Model
P48-NG2
Fuel Type
Natural Gas
Minimum Supply Pressure
5" W.C. (1.25 kPa)
Manifold Pressure - High
3.8" W.C. (0.95 kPa)
Manifold Pressure - Low
1.1" W.C. (0.27 kPa)
Orifi ce Size
#27 DMS - 0-4500ft
Minimum Input
29,000 BTU/h (8.49 kW)
Maximum Input
51,000 BTU/h (14.94 kW)
Vent Sizing
5" Inner / 8" Outer
Approved Venting Systems
Flex Vent Systems:
Rigid Pipe Vent Systems:
A
Unit Dimensions
Description
A
Front Face Width
B
Rear Firebox Width
C
Front Face Height
D
Height w/ Standoff
E
Unit Depth
F
Firebox Height
Framing Dimensions
Description
G
Framing Width
***
***
H
Framing Height
I
Framing Depth
J
Corner Wall Length
K
Corner Facing Wall Width
L
Framed Chase Ceiling
M
Vent Centerline Height
N
Gas Connection Height
O
Gas Connection Inset
P
Gas Connection Width
***
Important: Framing height requires consideration of the hearth
depth. Dimension H = H + the thickness of installed hearth.
June 2007 Regency Product Specifi cations Book
Gas Fireplaces
P48-LP2
Propane
12" W.C. (3.00 kPa)
11" W.C. (2.74 kPa)
3.3" W.C. (0.82 kPa)
#47 DMS
26,000 BTU/h (3.07 kW)
48,000 BTU/h (6.30 kW)
5" Inner / 8" Outer
FPI AstroCap™ Flex Vent
Simpson Dura-Vent® Direct Vent GS
B
A
C
D
F
E
P33
48" (1219mm)
34-1/2" (876mm)
41" (1041mm)
47" (1193mm)
23-1/4" (324mm)
40" (1016mm)
P33
48-1/2" (1232mm)
***
47-1/2" (1207mm)
29-3/4" (756mm) Vertical Rise
26-1/4" (667mm) No Vertical Rise
57-5/8 " (1464mm)
81-1/2" (2070mm)
N/A - Vertical Rise
50" (1270mm) No Vertical Rise
43" (1092mm)
2" (51mm)
3-3/4" (95mm)
5" (127mm)
H
G
J
K
Please refer to Page 11 (Exterior Vent Terminations)
for additional guidelines on vent locations.
P48 Gas Fireplace
L
Top Header
Drywall
(or other
facing)
11" (279mm)
dia. Hole through
wall Vent.
I
M
N
O P
Opening for gas
connection
61