INSTALLATION
THIS CONVERSION MUST BE DONE BY A QUALIFIED GAS FITTER
C
onversion Kit 486-967 Contains:
Qty. Part # Description
1 904-345 Burner Orifi ce #53
1 918-273 Red "ULPG" label
1 918-272 Label "Converted to ULPG"
1 910-037 LPG Pilot Injector
1 918-824 Instruction Sheet
1)
Shut off the gas supply and unplug
the power cord.
2)
Remove the glass door, logs and
lava rock.
3)
Remove the rear log tray by remov-
ing the 2 screws. (Log tray must be
rotated to clear the burner.)
4)
Remove the grate.
5)
Remove the burner and ensure the
aeration setting is 13 mm open.
6)
Remove burner orifi ce with a 1/2"
wrench and discard. Use a wrench
to hold on to the elbow behind the
orifi ce.
7)
Reinstall new burner orifi ce ULPG
stamped #53 and tighten.
8)
Apply the conversion label "This
unit has been converted to ULPG"
over top of the serial number decal.
Note: Aeration settings do not need
to be adjusted.
12

Conversion Kit #486-967 for NG to ULPG

IF IN DOUBT DO NOT DO THIS CONVERSION !!
9)
Pull out the pilot hood by hand.
Pilot
Hood
Pilot
Hood
removed
Pilot
Orifi ce
10) Remove the pilot orifi ce with the
allen key.
11) Put in the new LPG orifi ce with the
Burner
allen key. Then put back the pilot
hood.
12) Replace the yellow "NG" label with
the red "ULPG" label.
13) Carefully pull out the control box.
NOTE: The control box is held in
place with velcro.
14) Remove the heat shield from the
control box by removing the 2
screws.
15) Remove the control box cover by
undoing the 3 screws.
tenna.
Maneuver through an
Antenna
Control Box
Cover
16) Remove the jumper using a plier.
Jumper Location
Jumper
17) Reverse steps 13, 12, 11, 6, 5, 4, 3
& 2.