THIS CONVERSION MUST BE DONE BY A QUALIFIED GAS FITTER IF IN DOUBT DO NOT DO THIS CONVERSION !!
Conversion Kit 486-967 Contains:
Qty. Part #
Description
1 904-345
Burner Orifi ce #53
1 918-273
Red "ULPG" label
1 918-272
Label "Converted to ULPG"
1 918-542
Instruction Sheet
1) Shut off the gas supply and unplug the power
cord.
2) Remove the front door.
3) Remove logs.
4) Remove the rear log tray by removing the 2
screws. (Log tray must be rotated to clear
the burner.)
5) Remove the grate.
6) Remove the burner and adjust the aeration
setting to 15 mm fully open.
Regency IG35 Gas Inbuilt Fireplace

Conversion Kit #486-967 for NG to ULPG

7) Remove burner orifi ce with a 1/2" wrench
and discard. Use a wrench to hold on to the
elbow behind the orifi ce.
8) Reinstall new burner orifi ce ULPG stamped
#53 and tighten.
9) Stick the conversion label "This unit has
been converted to ULPG" over top of the
serial number decal.
10) Replace the yellow "NG" label with the red
"ULPG" label.
11) Carefully pull out the control box.
NOTE: The control box is held in place with
velcro.
12) Remove the heat shield from the control
box by removing the 2 screws.
Heat Shield
INSTALLATION
13) Remove the control box cover by undoing the
3 screws. Maneuver through antenna.
Antenna
Control Box
Cover
14) Remove the jumper using a plier.
Jumper Location
Jumper
15) Reverse steps 13, 12, 11, 6, 5, 4, 3 & 2.