Hobart Jet-Ex 5D Operation And Maintenance Manual page 15

500285 series generator sets
Table of Contents

Advertisement

OM-2094 / Operation and Maintenance Manual
Jet-Ex 5D / Series 500285 / Generator Set
Unit with Stationary Mount (500285-002)
Length
Width
Height
Weight (dry fuel tank)
Unit with Trailer and Cable Trays (500285-001)
Length
Width
Height
Weight (dry fuel tank)
Ground Clearance
Generator
Output Power Rating
Voltage
Rated Load Capacity
Starting Current Capacity
Current Limiting Capability
Operating Speed
Engine
Manufacturer
Model
Type
Fuel-Diesel recommended
Displacement
Rated Power at 2200 RPM
Oil Capacity (without filter change)
Coolant Capacity - engine only
Coolant Capacity - system
Electrical System
Governed Speed at No Load
Idle Speed
Fuel Tank Capacity
Protective Devices
Generator
Engine
November 1, 2000
Revised 07/01
68" (172.7 cm)
37" (94 cm)
46" (116.8 cm)
2400 lbs (1088.6 kg) Approx.
76.3" (193.8 cm)
67" (170.1 cm)
62" (157.5 cm)
2670 lbs (1211 kg) Approx.
14" (35.6 cm)
17.1 kW
28.5 volts DC
800 amperes continuous at 28.5 volts DC
2000 amperes maximum
300 to 2000 amperes, continuously adjustable
2500 +/-50 RPM
Cummins Diesel
4BT3.9
4-cylinder, 4-stroke, direct injection
ASTM D975 66T Numbers 1D or 2D
238 cubic inches (3.9 liters)
100 Horsepower (75 kW)
11.5 quarts (10.9 liters)
7.4 U.S. Quarts (7 liters)
4.5 U.S Gallons (17 liters)
12 volt DC, negative ground
2500 +/- 50 RPM
1000 +/- 50 RPM
20.5 U.S. gallons (77.6 liters)
28.5 volt over voltage module trips at 32 to 34 volts.
Water Temp. Switch opens engine circuit at 210º F (98.8º
C)
Low Oil Pressure Switch opens at 20 PSI (138 kPa).
Chapter 1-1
Page 3

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

500285-002500285-001

Table of Contents