Reimaging A Multiservices Platform Series Device That Is Running Vsm - Cisco CPS-MSP-1RU-K9 User Manual

Cisco physical security multiservices platform series
Table of Contents

Advertisement

Appendix B
Recovering from a Hard Drive Failure
Reimaging a Multiservices Platform Series Device that is
Running VSM
Reimaging a Multiservices Platform Series Device that is Running VSM involves reconfiguring RAID
to make replacement hard drives visible to the server and resetting the server to the factory defaults.
Before reimaging a system, replace all failed hard drives.
This procedure is intended to recover a server from a catastrophic failure. Before you perform these
Caution
steps, see
To reimage a server, perform the following steps:
Procedure
After replacing failed drives as described in the
Step 1
the server and, as soon as the server starts booting, press Ctrl-M to access the RAID configuration tool.
Choose Configure and press Enter.
Step 2
Choose New Configuration and press Enter.
Step 3
Choose Yes and press Enter to display the ports and drives.
Step 4
Choose Port 0 and press Spacebar to convert to ONLIN A00-00.
Step 5
Press F10 to configure.
Step 6
Press Spacebar to choose SPAN-1.
Step 7
Press F10 to continue.
Step 8
Step 9
Specify the following settings:
Choose Accept and press Enter to create VD0.
Step 10
Choose Accept and press Enter to create VD1.
Step 11
Press Esc to leave configuration mode and Yes to save the configuration.
Step 12
Press Esc again.
Step 13
For each additional drive:
Step 14
a.
b.
c.
d.
e.
f.
g.
h.
Step 15
Press Esc to return to the Management menu.
OL-21838-03
Table B-1
to make sure that this procedure is appropriate for your situation.
RAID = 0
Size = 12288
Select the next port and press Spacebar to change to ONLIN A0N-00, where N is the next drive.
Press F10 to configure.
Press Spacebar to choose SPAN-1.
Press F10 to continue.
Specify RAID = 0.
Choose Accept and press Enter.
Press Esc to leave configuration mode and Yes to save the configuration.
Press Esc again.

Reimaging a Multiservices Platform Series Device that is Running VSM

"Replacing a Hard Drive" section on page
Cisco Physical Security Multiservices Platform Series User Guide
B-3, reboot
B-5

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cps-msp-2ru-k9

Table of Contents