Replacing A Power Supply - Cisco CPS-MSP-1RU-K9 User Manual

Cisco physical security multiservices platform series
Table of Contents

Advertisement

Chapter 2
Setting Up and Maintaining the Multiservices Platform Series Device
Figure 2-8
Procedure
Step 1
Remove the chassis cover as described in the
To remove a fan, press and hold the release tab at the top of the fan and pull the fan straight up.
Step 2
To install a fan, slide the fan into a fan slot until it locks into place.
Step 3
The fan fits in only one way.
Replace the chassis cover.
Step 4

Replacing a Power Supply

The Multiservices Platform Series 2-RU model supports a second power supply for redundancy, which
allow the devices to continue to operate if one power supplies fails. If a power supply does fail, you
should replace it as soon as possible. Power supplies are hot swappable, which allows you to replace one
power supply at a time while the Multiservices Platform Series device is powered on.
Note
When you replace a power supply, make sure to replace it with the same model. The Cisco part number
for the power supply is CIVS-PS-900=.
OL-21838-03
Installing a Rear Fan
Cisco Physical Security Multiservices Platform Series User Guide
Multiservices Platform Series Maintenance Operations
"Removing the Chassis Cover" section on page
2-11.
2-13